Skip to main navigation Skip to search Skip to main content

Walrus large bore guide catheter impact on recanalization first pass effect and outcomes: The WICkED study

  • Gustavo M. Cortez
  • , Raymond D. Turner
  • , Andre Monteiro
  • , Ajit S. Puri
  • , Adnan H. Siddiqui
  • , J. Mocco
  • , Jan Vargas
  • , Anna L. Kuhn
  • , Shahram Majidi
  • , M. Imran Chaudry
  • , Amin Aghaebrahim
  • , Aquilla S. Turk
  • , Eric Sauvageau
  • , Ricardo A. Hanel
  • Baptist Neurological Institute
  • Jacksonville University
  • Prisma Health Upstate
  • SUNY Buffalo
  • University of Massachusetts Medical School
  • Icahn School of Medicine at Mount Sinai

Research output: Contribution to journalArticlepeer-review

17 Scopus citations

Abstract

Background The use of a balloon-guide catheter (BGC) in acute stroke treatment has been widely adopted after demonstrating optimized procedure metrics and outcomes. Initial technical constraints of previous devices included catheter stiffness and smaller inner diameters. We aim to evaluate the performance and safety of the Walrus BGC, a variable stiffness catheter with a large bore 0.087 inch inner diameter (ID), via the the WICkED study (Walrus Large Bore guide Catheter Impact on reCanalization first pass Effect anD outcomes). Methods This is a retrospective, site adjudicated, multicenter study on consecutive patients with large vessel occlusion treated with the Walrus BGC. Baseline characteristics, procedural outcomes and functional outcomes were analyzed. Results A total of 338 patients met the inclusion criteria. The Walrus was successfully tracked into distal vasculature and allowed therapeutic device delivery in all but 3 cases (0.9%). Large aspiration catheters ≥0.070 inch ID were used in 71.9% of cases. Stent retriever thrombectomy was used as the first-line modality in 59.2% and thromboaspiration in 40.8% of cases. The successful recanalization rate (modified treatment in cerebral ischemia (mTICI) 2b/3) was 94.4%, with 64.8% of the patients achieving mTICI 2b/3 after the first pass. The Walrus-related adverse event rate was 0.6%, corresponding to two vessel dissections. Functional independence was 50% (126/252) and mortality 25% (63/252). Unfavorable outcomes were more likely in older patients, who had unsuccessful reperfusion, longer procedure times, and a higher mean number of passes. Conclusion In acute ischemic stroke patients presenting with large vessel occlusion, the Walrus BGC demonstrated excellent navigability and safety profile, allowed the accommodation of leading large bore aspiration catheters, and demonstrated high vessel recanalization rates.

Original languageEnglish
Pages (from-to)280-285
Number of pages6
JournalJournal of NeuroInterventional Surgery
Volume14
Issue number3
DOIs
StatePublished - Mar 1 2022

Keywords

  • catheter
  • device
  • stroke
  • thrombectomy

Fingerprint

Dive into the research topics of 'Walrus large bore guide catheter impact on recanalization first pass effect and outcomes: The WICkED study'. Together they form a unique fingerprint.

Cite this