TY - GEN
T1 - Using respiratory signals for the recognition of human activities
AU - Ramos-Garcia, Raul I.
AU - Tiffany, Stephen
AU - Sazonov, Edward
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/10/13
Y1 - 2016/10/13
N2 - Human activity recognition through wearable sensors is becoming integral to health monitoring and other applications. Typically, human activity is captured through signals from inertial sensors, while signals from other sensors have been utilized less frequently. In this study, we explored the feasibility of classifying human activities by analyzing the temporal information of respiratory signals through hidden Markov models (HMMs). Left-to-right HMMs were trained for five activities: sedentary, walking, eating, talking, and cigarette smoking. The temporal information from every breathing segment was captured by fragmenting the tidal volume and airflow signals into smaller frames and computing features for each frame. These frames were used as observations to model the states of the HMMs through mixture of Gaussians. Using leave-one-out cross-validation, the classification performance showed an average precision, recall, and F-score of 60.37%, 67.01%, and 62.78%, respectively. Results suggest that respiratory signals can potentially be used as a primary or secondary source in the recognition of some human activities.
AB - Human activity recognition through wearable sensors is becoming integral to health monitoring and other applications. Typically, human activity is captured through signals from inertial sensors, while signals from other sensors have been utilized less frequently. In this study, we explored the feasibility of classifying human activities by analyzing the temporal information of respiratory signals through hidden Markov models (HMMs). Left-to-right HMMs were trained for five activities: sedentary, walking, eating, talking, and cigarette smoking. The temporal information from every breathing segment was captured by fragmenting the tidal volume and airflow signals into smaller frames and computing features for each frame. These frames were used as observations to model the states of the HMMs through mixture of Gaussians. Using leave-one-out cross-validation, the classification performance showed an average precision, recall, and F-score of 60.37%, 67.01%, and 62.78%, respectively. Results suggest that respiratory signals can potentially be used as a primary or secondary source in the recognition of some human activities.
UR - https://www.scopus.com/pages/publications/85009063865
U2 - 10.1109/EMBC.2016.7590668
DO - 10.1109/EMBC.2016.7590668
M3 - Conference contribution
C2 - 28268307
AN - SCOPUS:85009063865
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 173
EP - 176
BT - 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016
Y2 - 16 August 2016 through 20 August 2016
ER -