Skip to main navigation Skip to search Skip to main content

Use of 3D-printed patient-specific neurovascular phantoms to investigate the correlation between disease severity and quantitative angiography results

  • SUNY Buffalo
  • University of South Florida

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Purpose: 3D printed Patient-Specific Neurovascular Phantoms (3DP-PSNP) containing significant portions of the neurovasculature can be used to develop and test new diagnostic tools. The purpose of this research is to assess the use of 3DP-PSNP to study the correlation between Angiographic Parametric Imaging (API) features and the severity of carotid artery disease. Materials and Methods: We developed 3DP-PSNP for twenty patients with carotid atherosclerosis and performed two studies. In the first study, we used three phantoms with complete Circle of Willis (COW) with none, moderate and severe stenosis respectively. In the second experiment, all phantoms regardless of the COW structure were used. 3DP-PSNPs were connected in a simulated physiological pulsatile flow loop and Digital Subtractive Angiography (DSA) was performed by injecting 10 ml of contrast at 10 mL/s. An API software calculated imaging biomarkers: time-to-peak TTP, mean transit time MTT, time to arrival TTA, peak height PH, and area under the curve AUC for both carotids. Results: For none, moderate, and severe stenosis respectively, absolute mean percent differences between diseased vs. contralateral carotids were: 1.9%, 8.1%, 32.3% TTP; 6.8%, 7.5%, 41.0% TTA; 13.2%, 12.4%, 6.4% MTT; 8.7%, 11.3%, 97.6% PH; and 10.3%, 22.6%, 100% AUC. Injection parameters did not cause significant change to the difference between diseased and contralateral carotids. The second experiment showed strong correlation between the TTA and location of the stenosis, regardless of COW configuration. Conclusions: Overall, API was assessed in 3DP-PSNPs and shown to have increasing differences between diseased and contralateral carotid arteries with increasing severity.

Original languageEnglish
Title of host publicationMedical Imaging 2020
Subtitle of host publicationImaging Informatics for Healthcare, Research, and Applications
EditorsPo-Hao Chen, Thomas M. Deserno
PublisherSPIE
ISBN (Electronic)9781510634039
DOIs
StatePublished - 2020
EventMedical Imaging 2020: Imaging Informatics for Healthcare, Research, and Applications - Houston, United States
Duration: Feb 16 2020Feb 17 2020

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume11318
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2020: Imaging Informatics for Healthcare, Research, and Applications
Country/TerritoryUnited States
CityHouston
Period02/16/2002/17/20

Keywords

  • 3D printed patient-specific phantoms
  • 3D printing
  • Angiographic Parametric Imaging
  • Blood flow simulations
  • Neurovasculature

Fingerprint

Dive into the research topics of 'Use of 3D-printed patient-specific neurovascular phantoms to investigate the correlation between disease severity and quantitative angiography results'. Together they form a unique fingerprint.

Cite this