TU‐EE‐A4‐04: A New Antiscatter Grid for High‐Resolution Region‐Of‐Interest (ROI) X‐Ray Imaging

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: A new custom‐designed antiscatter grid for high‐resolution angiographic detectors is presented that would improve the image quality without introducing substantial grid‐line artifacts. Method and Materials: The new antiscatter grid is a custom‐made, parallel‐focus, crisscross cellular grid that employs gold septa material (CREATV MicroTech, Potomac, MD). The prototype 4.25 cm × 4.25 cm field‐of‐view grid has 20 μm thick septa with interspace distance of 380 μm, height 1.95 mm, and grid‐ratio of 5. This study was performed with the Microangiographic detector (43 μm pixel, 1024×1024 pixel matrix, 4.5 cm × 4.5 cm field‐of‐view, 250‐μm‐thick structured CsI(Tl) scintillator coupled to a CCD camera via minifying taper) in simulated neurovascular angiographic conditions, where a uniform head‐equivalent phantom was used as scattering media. The air‐gap between the phantom and the detector‐with‐grid was kept at 2.5 cm as used in clinical conditions for minimal blurring, but increased scatter. The standard lead‐beam‐stop technique was employed to determine the scatter‐fraction with and without the grid. In order to evaluate the low‐contrast imaging performance of the grid, phantoms with three different bone patterns of varying thickness and three different simulated iodinated vessel inserts in acrylic were imaged with and without‐grid at 70 kVp. Results: The grid demonstrated approximately 59% scatter reduction at 70 kVp for the uniform head‐equivalent phantom without introducing substantial grid‐line artifacts following flat‐field correction. The average contrast‐improvement‐factor for the low‐contrast vessel‐phantom was found to be 1.75, whereas for the relatively higher contrast bone‐phantom it was 1.5. The primary transmission factor was measured to be 66%. Conclusion: The grid demonstrated significant scatter reduction when used in simulated neurovascular angiographic conditions even for the small FOV. Use of this grid with the Micro‐angiographic detector with reduced air‐gap can provide substantially improved image quality. (Partial support: NIH R01‐NS43924, R01‐EB002873, Toshiba Medical System Corp.).

Original languageEnglish
Pages (from-to)2563
Number of pages1
JournalMedical Physics
Volume34
Issue number6
DOIs
StatePublished - Jun 2007

Fingerprint

Dive into the research topics of 'TU‐EE‐A4‐04: A New Antiscatter Grid for High‐Resolution Region‐Of‐Interest (ROI) X‐Ray Imaging'. Together they form a unique fingerprint.

Cite this