Thermal design of hot plate for 300-mm wafer heating in post-exposure bake

  • Jinho Lee
  • , Hyun Goo Kwon
  • , Sangwoo Shin
  • , Sangjo Han
  • , Jungik Ha
  • , Hosun Yoo
  • , Hyung Hee Cho
  • Yonsei University
  • Samsung

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Temperature uniformity of a wafer during post-exposure bake (PEB) in lithography is an important factor in controlling critical dimension (CD) uniformity. In this study, a new hot plate system for the PEB of a 300-mm wafer was analyzed and designed. First, temperature deviation on the wafer caused by warpage was investigated, and the heater pattern of the multi-zone hot plate in the bake system was numerically analyzed. Then, a new heater pattern to enhance the temperature uniformity was proposed and tested experimentally. As a result, temperature uniformity within 0.087 °C on a 300-mm wafer was achieved.

Original languageEnglish
Pages (from-to)3195-3198
Number of pages4
JournalMicroelectronic Engineering
Volume88
Issue number11
DOIs
StatePublished - Nov 2011

Keywords

  • 300-mm wafer
  • Hot plate
  • Post-exposure bake
  • Temperature uniformity

Fingerprint

Dive into the research topics of 'Thermal design of hot plate for 300-mm wafer heating in post-exposure bake'. Together they form a unique fingerprint.