Abstract
Temperature uniformity of a wafer during post-exposure bake (PEB) in lithography is an important factor in controlling critical dimension (CD) uniformity. In this study, a new hot plate system for the PEB of a 300-mm wafer was analyzed and designed. First, temperature deviation on the wafer caused by warpage was investigated, and the heater pattern of the multi-zone hot plate in the bake system was numerically analyzed. Then, a new heater pattern to enhance the temperature uniformity was proposed and tested experimentally. As a result, temperature uniformity within 0.087 °C on a 300-mm wafer was achieved.
| Original language | English |
|---|---|
| Pages (from-to) | 3195-3198 |
| Number of pages | 4 |
| Journal | Microelectronic Engineering |
| Volume | 88 |
| Issue number | 11 |
| DOIs | |
| State | Published - Nov 2011 |
Keywords
- 300-mm wafer
- Hot plate
- Post-exposure bake
- Temperature uniformity
Fingerprint