Abstract
A theoretical model is developed for the prediction of the peak to average particle deposition flux in the human bronchial airways. The model involves the determination of the peak flux by a round-nose 2-dimensional bifurcation channel and the average deposition flux by a curved-tube model. The “hot-spot” effect for all generations in the human respiratory system is estimated. It is found that the peak deposition flux is higher than the average deposition flux by a factor ranging between 5 and 30, depending on the generation number. The importance of this peak to average deposition flux ratio on consideration of environmental safety studies is discussed.
| Original language | English |
|---|---|
| Pages (from-to) | 195-201 |
| Number of pages | 7 |
| Journal | American Industrial Hygiene Association Journal |
| Volume | 39 |
| Issue number | 3 |
| DOIs | |
| State | Published - Mar 1 1978 |