Skip to main navigation Skip to search Skip to main content

The Silk Vista Baby Study: A Multicenter Aneurysm Report From North America and Europe

  • Ricardo A. Hanel
  • , Otavio F. de Toledo
  • , Natalia V. De Oliveira Souza
  • , Salvador F. Gutierrez-Aguirre
  • , Monika Killer-Oberpfalzer
  • , Eytan Raz
  • , Maksim Shapiro
  • , Tareq Kass-Hout
  • , Michael Hurley
  • , Rami Z. Morsi
  • , Visish M. Srinivasan
  • , Brian T. Jankowitz
  • , Pierce Davis
  • , Adnan Siddiqui
  • , Vinay Jaikumar
  • , Gustavo M. Cortez
  • , Omar Kass-Hout
  • , Tibor Becske
  • , Ramesh Grandhi
  • , Craig Kilburg
  • Demetrius K. Lopes, Andrew F. Ducruet, Lucas Elijovich, Gavin Britz, Maria M. Toledo, Joshua Seinfeld, Robert M. Starke, Raul G. Nogueira, Matthew T. Bender, Peter T. Kan, Tyler Lazaro, Victor H.C. Benalia, Fernanda R. Erazu, Montserrat Lara-Velazquez, Amin Aghaebrahim, Eric Sauvageau, Vitor M. Pereira
  • Baptist Neurological Institute
  • Jacksonville University
  • University of Toronto
  • University Hospital Salzburg
  • New York University
  • The University of Chicago
  • University of Pennsylvania
  • SUNY Buffalo
  • UNC-Rex Healthcare
  • University of Utah
  • Advocate Aurora Health
  • St. Joseph's Hospital and Medical Center, Phoenix
  • Semmes-Murphey Neurologic and Spine Institute
  • Houston Methodist
  • Ascension Sacred Heart Hospital
  • University of Colorado Anschutz Medical Campus
  • University of Miami
  • University of Pittsburgh
  • University of Rochester
  • University of Texas Medical Branch at Galveston
  • Baylor College of Medicine

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

BACKGROUND AND OBJECTIVES: – The Silk Vista Baby (SVB) flow diverter (FD) stent (Balt SAS) is the first device designed for treating distally located brain aneurysms. It can be delivered through a 0.017-inch ID microcatheter, enabling access to small, distal vessels. The aim of this study was to evaluate the effectiveness, safety, technical success, occlusion rate, and clinical outcomes of the SVB device.METHODS: – This retrospective, multicenter study included data from 18 centers from November 2023 to September 2024. Procedures were performed by experienced neurointerventionalists following institutional standards of care. Outcomes analyzed included effectiveness, safety, and aneurysm occlusion rates. Descriptive analyses and Pearson χ2 or Independent t-Test were used for statistical evaluation.RESULTS: – A total of 95 patients, mean age 55.4 years, were included. A total of 31% of aneurysms were ruptured at admission. Most (58.3%) were located in the anterior circulation, and 45% had previous treatment, mainly coiling (69.4%). Complication rates were higher for ruptured aneurysms (24.1%) compared with unruptured ones (9.2%). Two deaths occurred, 1 (1.1%) related to the procedure. At discharge, 87% of patients had modified Rankin Scale ≤2. The latest follow-up showed overall complete/near-complete occlusion rates of 76.1%, with 81.14% for ruptured and 73.43% for unruptured aneurysms. Technical success was higher in unruptured cases (100% vs 93.1%).CONCLUSION: – Our case series demonstrated the efficacy of the SVB with a high rate of technical success. The occlusion rates for ruptured cases are comparable with those of other FDs. However, the rates are lower for unruptured cases. This discrepancy is likely due to the characteristics of the aneurysms, particularly in the presence of side branches in bifurcation lesions. The SVB safety profile is similar to other FDs in unruptured cases, while the ruptured group presented more complications.

Original languageEnglish
Pages (from-to)464-473
Number of pages10
JournalNeurosurgery
Volume98
Issue number2
DOIs
StatePublished - Feb 2026

Keywords

  • Aneurysm
  • Flow diverter
  • Silk Vista Baby
  • Small vessels

Fingerprint

Dive into the research topics of 'The Silk Vista Baby Study: A Multicenter Aneurysm Report From North America and Europe'. Together they form a unique fingerprint.

Cite this