Skip to main navigation Skip to search Skip to main content

The radioactive source calibration system of the PROSPECT reactor antineutrino detector

  • J. Ashenfelter
  • , A. B. Balantekin
  • , H. R. Band
  • , C. D. Bass
  • , D. E. Bergeron
  • , D. Berish
  • , N. S. Bowden
  • , J. P. Brodsky
  • , C. D. Bryan
  • , J. J. Cherwinka
  • , T. Classen
  • , A. J. Conant
  • , D. Dean
  • , G. Deichert
  • , M. V. Diwan
  • , M. J. Dolinski
  • , A. Erickson
  • , M. Febbraro
  • , B. T. Foust
  • , J. K. Gaison
  • A. Galindo-Uribarri, C. E. Gilbert, B. T. Hackett, S. Hans, A. B. Hansell, K. M. Heeger, J. Insler, D. E. Jaffe, D. C. Jones, O. Kyzylova, C. E. Lane, T. J. Langford, J. LaRosa, B. R. Littlejohn, X. Lu, D. A.Martinez Caicedo, J. T. Matta, R. D. McKeown, M. P. Mendenhall, P. E. Mueller, H. P. Mumm, J. Napolitano, R. Neilson, J. A. Nikkel, D. Norcini, S. Nour, D. A. Pushin, X. Qian, E. Romero-Romero, R. Rosero, D. Sarenac, P. T. Surukuchi, A. B. Telles, M. A. Tyra, R. L. Varner, B. Viren, C. White, J. Wilhelmi, T. Wise, M. Yeh, Y. R. Yen, A. Zhang, C. Zhang, X. Zhang
  • Yale University
  • University of Wisconsin-Madison
  • Le Moyne College
  • National Institute of Standards and Technology
  • Temple University
  • Lawrence Livermore National Laboratory
  • Oak Ridge National Laboratory
  • Georgia Institute of Technology
  • Oak Ridge National Laboratory
  • Brookhaven National Laboratory
  • Drexel University
  • University of Tennessee
  • Illinois Institute of Technology
  • College of William and Mary
  • University of Waterloo

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c2 and to measure the spectrum of electron antineutrinos from a highly-enriched 235U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in 6Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.

Keywords

  • Calibration
  • Detector
  • Neutrino
  • Radioactive source
  • Reactor
  • Scintillator

Fingerprint

Dive into the research topics of 'The radioactive source calibration system of the PROSPECT reactor antineutrino detector'. Together they form a unique fingerprint.

Cite this