Abstract

The ZEUS detector at HERA has been supplemented with a presampler detector in front of the forward and rear calorimeters. It consists of a segmented scintillator array read out with wavelength-shifting fibers. We discuss its design, construction and performance. Test beam data obtained with a prototype presampler and the ZEUS prototype calorimeter demonstrate the main function of this detector, i.e. the correction for the energy lost by an electron interacting in inactive material in front of the calorimeter.

Original languageEnglish
Pages (from-to)419-429
Number of pages11
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume382
Issue number3
DOIs
StatePublished - Nov 21 1996

Fingerprint

Dive into the research topics of 'The presampler for the forward and rear calorimeter in the ZEUS detector'. Together they form a unique fingerprint.

Cite this