The micro-angiographic fluoroscope (MAF) in High Definition (HD) mode for improved contrast-to-noise ratio and resolution in fluoroscopy and roadmapping

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

7 Scopus citations

Abstract

During image guided interventional procedures, superior resolution and image quality is critically important. Operating the MAF in the new High Definition (HD) fluoroscopy mode provides high resolution and increased contrast-to-noise ratio. The MAF has a CCD camera and a 300 micron cesium iodide x-ray convertor phosphor coupled to a light image intensifier (LII) through a fiber-optic taper. The MAF captures 1024 × 1024 pixels with an effective pixel size of 35 microns, and is capable of real-time imaging at 30 fps. The HD mode uses the advantages of higher exposure along with a small focal spot effectively improving the contrast-to-noise ratio (CNR) and the spatial resolution. The Control Acquisition Processing and Image Display System (CAPIDS) software for the MAF controls the LII gain. The interventionalist can select either fluoroscopic or angiographic modes using the two standard foot pedals. When improved image quality is needed and the angiography foot-pedal is used for HD mode, the x-ray machine will operate at a preset higher exposure rate using a small focal spot, while the CAPIDS will automatically adjust the LII gain to achieve proper image brightness. HD mode fluoroscopy and roadmapping are thus achieved conveniently during the interventional procedure. For CNR and resolution evaluation we used a bar phantom with images taken in HD mode with both the MAF and a Flat Panel Detector (FPD). It was seen that the FPD could not resolve more than 2.8 lp/mm whereas the MAF could resolve more than 5 lp/mm. The CNR of the MAF was better than that of the FPD by 60% at lower frequencies and by 600% at the Nyquist frequency of the FPD. The HD mode has become the preferred mode during animal model interventions because it enables detailed features of endovascular devices such as stent struts to be visualized clearly for the first time. Clinical testing of the MAF in HD mode is imminent.

Original languageEnglish
Title of host publicationIEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010
Pages3217-3220
Number of pages4
DOIs
StatePublished - 2010
Event2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 - Knoxville, TN, United States
Duration: Oct 30 2010Nov 6 2010

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Conference

Conference2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
Country/TerritoryUnited States
CityKnoxville, TN
Period10/30/1011/6/10

Fingerprint

Dive into the research topics of 'The micro-angiographic fluoroscope (MAF) in High Definition (HD) mode for improved contrast-to-noise ratio and resolution in fluoroscopy and roadmapping'. Together they form a unique fingerprint.

Cite this