Skip to main navigation Skip to search Skip to main content

The effect of scanned area on the accuracy and time of anterior single implant scans: An in vitro study

  • University of Bern
  • Ohio State University

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Objectives: To investigate the effect of scanned area on the accuracy and scan time of intraoral scans of an anterior implant. Materials and methods: Three operators experienced in intraoral scanning (at least 2-year experience) performed partial and complete-arch scans (n = 10) of a dentate resin model with an implant at left central incisor site by using an intraoral scanner (Trios3; 3Shape, Copenhagen, Denmark). Each partial- or complete-arch scan was superimposed to a reference scan from a laboratory scanner (Ceramill Map 600; Amann Girrbach AG). Mean distance (selected 7 points) and angular (mesiodistal and buccolingual) scanbody deviations in test scans (trueness) and their variance (precision) were calculated. Linear-regressions (trueness), two-sided F-tests with a Bonferroni correction (precision), and multiple linear regressions (scan time), with the operator as a covariate were applied (alpha =.05). Results: Interactions were found between the scanned area and the operator for their effect on trueness of all points and angles, except for point 6 at implant-abutment connection in mesiodistal plane (p <.05). No significant difference was found between the precision of partial and complete-arch scans for all operators (p >.05). Partial-arch scan times were significantly shorter, overall, and for each operator (p <.001). No significant effect of scan time was found on the trueness of partial- and complete-arch scans (p >.05). Conclusions: Partial and complete-arch scans of anterior single implants with an intraoral scanner resulted in similar accuracies, and were not influenced by the operator or the scan time. Scan times of partial-arch scans were significantly shorter. Clinical significance: Partial-arch scans can be used for the fabrication of monolithic anterior single implant crowns because the scans can be completed in shorter times without compromising the accuracy.

Original languageEnglish
Article number103620
JournalJournal of Dentistry
Volume109
DOIs
StatePublished - Jun 2021

Keywords

  • Accuracy
  • Implant crown
  • Implant scan
  • Intraoral scan
  • Operator influence

Fingerprint

Dive into the research topics of 'The effect of scanned area on the accuracy and time of anterior single implant scans: An in vitro study'. Together they form a unique fingerprint.

Cite this