Skip to main navigation Skip to search Skip to main content

Study of the effect of boundary conditions on fractional flow reserve using patient specific coronary phantoms

  • Kelsey N. Sommer
  • , Lauren M. Shepard
  • , Vijay Iyer
  • , Erin Angel
  • , Michael F. Wilson
  • , Frank J. Rybicki
  • , Dimitrios Mitsouras
  • , Ciprian N. Ionita
  • SUNY Buffalo
  • Canon Inc.
  • University of Cincinnati
  • Brigham and Women’s Hospital

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

2 Scopus citations

Abstract

Purpose: 3D printing has become an accepted radiological tool which allow accurate physical renderings of organs for diagnosis and treatment planning. Use of 3D printed phantoms to replicate blood flow conditions have been reported, however, comprehensive studies comparing in-patients and in-vitro measurements are scarce. We propose to study whether 3D-printed patient specific coronary benchtop models, can be used to study how variations in outflow boundary conditions influence benchtop fractional flow reserve (FFR) measurements and how these compare with a research CT-FFR software. Materials and Methods: Fifty-two CT-derived patient-specific 3D-printed coronary phantoms were used for comprehensive flow experiments and a benchtop-FFR (B-FFR) was evaluated along the diseased arteries. A programmable cardiac pulsatile pump provided six coronary outflow rates equally distributed between normal and hyperemic blood flow conditions (250-500 mL/min). B-FFR results were compared to catheter lab Invasive-FFR (I-FFR) measurements and a CT-FFR research software. The effect of coronary outflow changes was compared with catheter lab diagnosis using operator characteristics (ROC) and Area Under ROC (AUROC). Results: The highest AUROC was for B-FFR-500, 0.82 (95% CI: 0.65-0.92,), and gradually decreased as the flow rate decreased to B-FFR-250, 0.79 (95% CI: 0.70-0.87). The CT-FFR AUROC was 0.80 (95% CI: 0.69-0.86). Conclusion: 3D-printed patient specific coronary phantoms and controlled flow experiments demonstrated significant agreement between hyperemic simulated flow B-FFR-500 and I-FFR. We also observed not negligible variations of the B-FFR for small coronary outflow rates changes, implying that slight changes in outflow conditions may results in diagnosis change, especially in the 0.75-0.85 FFR range.

Original languageEnglish
Title of host publicationMedical Imaging 2020
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
EditorsAndrzej Krol, Barjor S. Gimi
PublisherSPIE
ISBN (Electronic)9781510634015
DOIs
StatePublished - 2020
EventMedical Imaging 2020: Biomedical Applications in Molecular, Structural, and Functional Imaging - Houston, United States
Duration: Feb 18 2020 → Feb 20 2020

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume11317
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2020: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CityHouston
Period02/18/20 → 02/20/20

Keywords

  • 3D Printing
  • Coronary Artery Disease
  • Coronary CT Angiography
  • CT-FFR
  • Fractional Flow Reserve

Fingerprint

Dive into the research topics of 'Study of the effect of boundary conditions on fractional flow reserve using patient specific coronary phantoms'. Together they form a unique fingerprint.

Cite this