Skip to main navigation Skip to search Skip to main content

Specificity of the DPD and amperometric titration methods for free available chlorine. A review

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Both the DPD and amperometric titration methods for measuring free available chlorine (FAC) are subject to interference from monochloramine and organic chloramines. The measured FAC concentration in the presence of chloramines is often significantly larger than the true FAC residual. Interference in the DPD method can be reduced by rapid titrations. Interference in the amperometric titration method can be minimized by maintaining a 200-mV positive potential on the platinum electrode.

Original languageEnglish
Pages (from-to)59-64
Number of pages6
JournalJournal - American Water Works Association
Volume81
Issue number12
DOIs
StatePublished - 1989

Fingerprint

Dive into the research topics of 'Specificity of the DPD and amperometric titration methods for free available chlorine. A review'. Together they form a unique fingerprint.