Skip to main navigation Skip to search Skip to main content

Shaking table tests of pinned-base steel gable frame

  • J. S. Hwang
  • , K. C. Chang
  • , G. C. Lee
  • , R. L. Ketter
  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

In the United States design of steel gable frames normally follows the guidelines prescribed by the American Institute of Steel Construction for assumed wind and gravity loadings In this study a pinned-base steel gable frame structure composed of prismatic members is constructed and the dynamic characteristics of that structure are investigated using the shaking table The tests are carried well into the inelastic range so that ultimate lateral strength under seismic excitation can be quantified It is observed that for such structures the response modification factor adopted by the Applied Technology Council (ATC) should be assumed with caution In addition the excessive elastic and inelastic story drifts which are attributed to the pinned-base condition require careful evaluation to ensure structural safety against large sidesways The excessive story drift is likely one of the major reasons for the severe nonstructural damage of steel gable framesduring the 1985 Chile earthquake and the 1987 Edgecumbe earthquake

Original languageEnglish
Pages (from-to)3031-3043
Number of pages13
JournalJournal of Structural Engineering (United States)
Volume115
Issue number12
DOIs
StatePublished - Dec 1989

Fingerprint

Dive into the research topics of 'Shaking table tests of pinned-base steel gable frame'. Together they form a unique fingerprint.

Cite this