Skip to main navigation Skip to search Skip to main content

Sensitivity of the two-dimensional electric potential/resistance method for damage monitoring in carbon fiber polymer-matrix composite

  • SUNY Buffalo
  • Global Contour Ltd.

Research output: Contribution to journalArticlepeer-review

44 Scopus citations

Abstract

The two-dimensional electric potential/resistance method is much less sensitive than the one-dimensional resistance method for damage monitoring in carbon fiber polymer-matrix composite. In the two-dimensional method, the resistance measurement is more sensitive than the potential gradient measurement. The sensitivity of the potential method is enhanced when the potential gradient line is close to the current line.

Original languageEnglish
Pages (from-to)4839-4846
Number of pages8
JournalJournal of Materials Science
Volume41
Issue number15
DOIs
StatePublished - Aug 2006

Fingerprint

Dive into the research topics of 'Sensitivity of the two-dimensional electric potential/resistance method for damage monitoring in carbon fiber polymer-matrix composite'. Together they form a unique fingerprint.