Skip to main navigation Skip to search Skip to main content

Self-monitoring in carbon fiber reinforced mortar by reactance measurement

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

110 Scopus citations

Abstract

Self-monitoring in carbon fiber reinforced mortar was demonstrated by AC impedance measurement. The reactance X, was found to be a more sensitive indicator of strain than the resistance R,. The fractional increase in X, was 38 at compressive failure, while the fractional increase in R, was 23, for mortar with methylcellulose, silica fume and fibers (0.35 vol.%).

Original languageEnglish
Pages (from-to)845-852
Number of pages8
JournalCement and Concrete Research
Volume27
Issue number6
DOIs
StatePublished - Jun 1997

Fingerprint

Dive into the research topics of 'Self-monitoring in carbon fiber reinforced mortar by reactance measurement'. Together they form a unique fingerprint.

Cite this