TY - GEN
T1 - Seismic response analysis of structures equipped with uplift-restraining sliding isolation bearings
T2 - 8th US National Conference on Earthquake Engineering 2006
AU - Roussis, P. C.
AU - Constantinou, M. C.
PY - 2006
Y1 - 2006
N2 - This paper concentrates on the seismic response analysis of structures equipped with uplift-restraining sliding isolation bearings (XY-FP). The study involves nonlinear response-history analysis of a seismically isolated building, the new Acropolis Museum in Athens, Greece, subjected to bi-directional horizontal seismic excitation. The analysis was performed with an enhanced version of program 3D-BASIS-ME, which was modified to include an element representative of the mechanical behavior of the XY-FP isolators. Upon identifying the uplift-prone isolators through analysis of the seismically isolated structure equipped with solely conventional Friction Pendulum (FP) isolators, 3D-BASIS-ME analysis was performed on the structure with isolators prone to uplift being replaced with XY-FP isolators. The input motions used in the analysis were arbitrarily scaled so that they cause significant uplift in the FP isolators or significant tension in the XY-FP isolators, in order to ascertain the impact of using the XY-FP isolators in a real structure. The results demonstrate that tension in individual XY-FP isolators, and by extension the increase of isolation system friction force, did not have any appreciable effect on either the total isolation system response or the superstructure response.
AB - This paper concentrates on the seismic response analysis of structures equipped with uplift-restraining sliding isolation bearings (XY-FP). The study involves nonlinear response-history analysis of a seismically isolated building, the new Acropolis Museum in Athens, Greece, subjected to bi-directional horizontal seismic excitation. The analysis was performed with an enhanced version of program 3D-BASIS-ME, which was modified to include an element representative of the mechanical behavior of the XY-FP isolators. Upon identifying the uplift-prone isolators through analysis of the seismically isolated structure equipped with solely conventional Friction Pendulum (FP) isolators, 3D-BASIS-ME analysis was performed on the structure with isolators prone to uplift being replaced with XY-FP isolators. The input motions used in the analysis were arbitrarily scaled so that they cause significant uplift in the FP isolators or significant tension in the XY-FP isolators, in order to ascertain the impact of using the XY-FP isolators in a real structure. The results demonstrate that tension in individual XY-FP isolators, and by extension the increase of isolation system friction force, did not have any appreciable effect on either the total isolation system response or the superstructure response.
UR - https://www.scopus.com/pages/publications/84865847471
M3 - Conference contribution
AN - SCOPUS:84865847471
SN - 9781615670444
T3 - 8th US National Conference on Earthquake Engineering 2006
SP - 7794
EP - 7804
BT - 8th US National Conference on Earthquake Engineering 2006
Y2 - 18 April 2006 through 22 April 2006
ER -