Abstract

Full-scale dynamic testing of suspended ceiling systems was performed to obtain fragility data suitable for performance-based assessment and design. On the basis of the fragility data derived from testing, (1) the use of retainer clips improves the performance of ceiling systems in terms of loss of tiles, (2) including recycled cross tees in the suspension grid increases the vulnerability of the ceiling systems, (3) undersized (poorly fitting) tiles are substantially more vulnerable than properly fitted tiles, and (4) the use of compression posts improves the seismic performance of ceiling systems for the limit states of minor and moderate damage. Fragility curves are provided for four damage states.

Original languageEnglish
Pages (from-to)21-40
Number of pages20
JournalEarthquake Spectra
Volume23
Issue number1
DOIs
StatePublished - Feb 2007

Fingerprint

Dive into the research topics of 'Seismic fragility of suspended ceiling systems'. Together they form a unique fingerprint.

Cite this