Skip to main navigation Skip to search Skip to main content

Reproducibility and accuracy of quantitative magnetic resonance imaging techniques of whole-brain atrophy measurements in multiple sclerosis

  • University of Trieste
  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

Background and Purpose. Whole-brain atrophy is of growing interest as an outcome measure in multiple sclerosis (MS) clinical trials. The authors compared the reproducibility and accuracy of 3 quantitative techniques of measurement in patients with MS. Methods. Thirty-four patients with relapsing-remitting MS (median Expanded Disability Status Scale disability score = 1.5) were studied. Brain parenchymal fraction (BPF) was quantified on spin-echo 2-dimensional T1-weighted axial 5-mm slice thickness sequences by semiautomated (Buffalo, Trieste) or automated (SIENAX) algorithms. Results. Mean ± SD BPFs were 0.830 ± 0.04 with Buffalo, 0.824 ± 0.04 with Trieste, and 0.826 ± 0.04 with SIENAX methods (P = nonsignificant [NS]). Mean BPF scanrescan coefficient of variation (COV) was 0.41% for Buffalo, 0.44% for Trieste, and 0.32% for SIENAX (P = NS). The semiautomated methods showed higher accuracy than the automated method in brain extraction (masking; P = .001). The errors of skull stripping included scalp, skull bone marrow, inferior parts of temporal lobes anterior to the brain stem, face structures, sagittal sinuses, eyes, and optic nerves. Buffalo (r = -0.37, P = .034) and Trieste (r = -.36, P = .039) BPFs showed stronger correlation with disability than SIENAX (r =-0.16, P = .219). These differences were statistically significant (P = .0031 for Buffalo and P = .0037 for Trieste BPF). Conclusions. This study showed a high reproducibility of both semiautomated and automated methods for brain atrophy measurement. The semiautomated methods showed higher accuracy than the automated SIENAX method did in the evaluation of brain extraction, especially in infratentorial and cortical regions, where operator interaction during the masking processes was essential.

Original languageEnglish
Pages (from-to)27-36
Number of pages10
JournalJournal of Neuroimaging
Volume15
Issue number1
DOIs
StatePublished - Jan 2005

Keywords

  • Accuracy
  • Brain atrophy
  • MRI
  • Multiple sclerosis
  • Quantitative techniques
  • Reproducibility

Fingerprint

Dive into the research topics of 'Reproducibility and accuracy of quantitative magnetic resonance imaging techniques of whole-brain atrophy measurements in multiple sclerosis'. Together they form a unique fingerprint.

Cite this