Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector

  • SUNY Buffalo
  • Toshiba Medical Research Institute

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

7 Scopus citations

Abstract

Cone beam computed tomography (CBCT) systems with rotational gantries that have standard flat panel detectors (FPD) are widely used for the 3D rendering of vascular structures using Feldkamp cone beam reconstruction algorithms. One of the inherent limitations of these systems is limited resolution (<;3 lp/mm). There are systems available with higher resolution but their small FOV limits them to small animal imaging only. In this work, we report on region-of-interest (ROI) CBCT with a high resolution CMOS detector (75 μm pixels, 600 μm HR-CsI) mounted with motorized detector changer on a commercial FPD-based C-arm angiography gantry (194 μm pixels, 600 μm HL-CsI). A cylindrical CT phantom and neuro stents were imaged with both detectors. For each detector a total of 209 images were acquired in a rotational protocol. The technique parameters chosen for the FPD by the imaging system were used for the CMOS detector. The anti-scatter grid was removed and the incident scatter was kept the same for both detectors with identical collimator settings. The FPD images were reconstructed for the 10 cm x10 cm FOV and the CMOS images were reconstructed for a 3.84 cm x 3.84 cm FOV. Although the reconstructed images from the CMOS detector demonstrated comparable contrast to the FPD images, the reconstructed 3D images of the neuro stent clearly showed that the CMOS detector improved delineation of smaller objects such as the stent struts (∼70 μm) compared to the FPD. Further development and the potential for substantial clinical impact are suggested.

Original languageEnglish
Title of host publicationMedical Imaging 2015
Subtitle of host publicationPhysics of Medical Imaging
EditorsChristoph Hoeschen, Despina Kontos, Christoph Hoeschen
PublisherSPIE
ISBN (Electronic)9781628415025
DOIs
StatePublished - 2015
EventMedical Imaging 2015: Physics of Medical Imaging - Orlando, United States
Duration: Feb 22 2015Feb 25 2015

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9412
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2015: Physics of Medical Imaging
Country/TerritoryUnited States
CityOrlando
Period02/22/1502/25/15

Fingerprint

Dive into the research topics of 'Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector'. Together they form a unique fingerprint.

Cite this