Abstract

Photon counting detectors (PCDs) with their low noise, high spatial and contrast resolution, and dual energy imaging capabilities are shown to be prospective candidates for Cone-Beam CT (CBCT) vascular imaging. The ultra-high frame rate capability of such detectors can enable CBCT at scan speeds far greater than that of current CBCT scanners which can only go up to about 0.14 rev/s (50 degrees/sec) compared to current multislice CT scanners that can achieve 3-4 rev/s. XCounter's Actaeon PCD with frame rates up to 1000 fps can achieve CBCT scans at multi-slice CT scanner rates. The CdTe Actaeon PCD with pixel pitch of 100 μm and dual energy direct acquisition capability has built-in electronic anti-charge sharing correction. CBCT of a moving wire was demonstrated with the Actaeon PCD at these higher speeds and shown to be able to eliminate the effect of acquisition system image motion blur. Also a patient-specific 3D printed vascular phantom with a stent deployed was imaged at high frame rates using the Actaeon for CBCT acquisition with reconstruction using an FDK algorithm and the maximum intensity projection images clearly showed individual strut detail. This feasibility study will lead to exploration of new possibilities of high frame-rate imaging with PCDs and their potential applications.

Original languageEnglish
Title of host publicationMedical Imaging 2019
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
EditorsBarjor Gimi, Andrzej Krol
PublisherSPIE
ISBN (Electronic)9781510625532
DOIs
StatePublished - 2019
EventMedical Imaging 2019: Biomedical Applications in Molecular, Structural, and Functional Imaging - San Diego, United States
Duration: Feb 19 2019Feb 21 2019

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10953
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2019: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CitySan Diego
Period02/19/1902/21/19

Keywords

  • CBCT
  • High Frame Rate Imaging
  • Photon Counting Detectors (PCD)
  • Vascular Imaging

Fingerprint

Dive into the research topics of 'Rapid cone-beam computed tomography using an ultra-high frame rate imaging photon counting detector (PCD) with 100 μm resolution'. Together they form a unique fingerprint.

Cite this