Skip to main navigation Skip to search Skip to main content

Quantitative mass spectrometry of technical polymers: A comparison of several ionization methods

  • SUNY Buffalo
  • Bausch & Lomb Incorporated

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

The development of soft ionization methods such as matrix-assisted laser desorption/ionization (MALDI), electrospray ionization (ESI) and secondary ion mass spectrometry (SIMS) has led to an increased use of mass spectrometry in characterizing technical (synthetic) polymers. In this paper, we compare the relative performance of these three ionization methods for characterizing the molecular weights, polydispersities and quantification of relative amounts of polymer components in mixtures. Two polymers used in biomaterials, poly(dimethylsiloxane) and poly(ethylene glycol), are employed as the model polymer systems for our survey because of their well-defined molecular weights and importance as surfactants in biomaterials and because many of their surface and solution-phase properties are well understood. Matrix-assisted laser desorption/ionization can be used to examine the surface and bulk composition of biomaterials, whereas secondary ion mass spectrometry is used for examining monolayer and submonolayer coverage of polymers on surfaces and electrospray ionization is suited for examination of extractables from biomaterials. Secondary ion mass spectrometry and electrospray show discriminate behavior against ionization of higher molecular weight oligomers, especially of poly(dimethylsiloxane). Matrix-assisted laser desorption/ionization appears to exhibit the best performance for reliable molecular weight determination at higher masses and polydispersity characterization as well as for quantification of components in polymer mixtures. The results are discussed within the context of the ionization mechanisms by which each soft ionization technique operates and by the attributes of the mass analyzers (time-of-flight and Fourier transform mass spectrometers) employed.

Original languageEnglish
Pages (from-to)467-474
Number of pages8
JournalEuropean Journal of Mass Spectrometry
Volume4
Issue number6
DOIs
StatePublished - 1998

Keywords

  • Electrospray ionization
  • Fourier transform mass spectrometry
  • Matrix-assisted laser desorption/ionization
  • Poly(dimethylsiloxane)
  • Poly(ethylene glycol)
  • Polymer
  • Quantitation
  • Secondary ion mass spectrometry
  • Time-of-flight mass spectrometry

Fingerprint

Dive into the research topics of 'Quantitative mass spectrometry of technical polymers: A comparison of several ionization methods'. Together they form a unique fingerprint.

Cite this