Skip to main navigation Skip to search Skip to main content

Primary results of the multicenter ARISE II study (Analysis of Revascularization in Ischemic Stroke With EmboTrap)

  • Osama O. Zaidat
  • , Hormozd Bozorgchami
  • , Marc Ribó
  • , Jeffrey L. Saver
  • , Heinrich P. Mattle
  • , René Chapot
  • , Ana Paula Narata
  • , Olivier Francois
  • , Ashutosh P. Jadhav
  • , Jonathan A. Grossberg
  • , Christian H. Riedel
  • , Alejandro Tomasello
  • , Wayne M. Clark
  • , Hannes Nordmeyer
  • , Eugene Lin
  • , Raul G. Nogueira
  • , Albert J. Yoo
  • , Tudor G. Jovin
  • , Adnan H. Siddiqui
  • , Thierry Bernard
  • Mairsíl Claffey, Tommy Andersson
  • Mercy Health, Ohio
  • Oregon Health and Science University
  • Vall d'Hebron University Hospital
  • University of California at Los Angeles
  • University of Bern
  • Alfried Krupp Krankenhaus
  • Centre Hospitalier Régional Universitaire de Tours
  • AZ Groeninge
  • University of Pittsburgh
  • Emory University
  • University Heart Center Hamburg
  • Texas Stroke Institute
  • Johnson & Johnson
  • Neuravi Ltd
  • Karolinska Institutet

Research output: Contribution to journalArticlepeer-review

143 Scopus citations

Abstract

Background and Purpose-EmboTrap is a novel stent retriever designed to achieve rapid and substantial flow restoration in acute ischemic stroke secondary to large-vessel occlusions. Here, we evaluated EmboTrap's safety and efficacy compared with established stent retrievers. Methods-ARISE II (Analysis of Revascularization in Ischemic Stroke With EmboTrap) was a single-arm, prospective, multicenter study, comparing the EmboTrap device to a composite performance goal criterion derived using a Bayesian meta-analysis from the pivotal SWIFT (Solitaire device) and TREVO 2 (Trevo device) trials. Patients at 11 US and 8 European sites were eligible for inclusion if they had large-vessel occlusions and moderate-to-severe neurological deficits within 8 hours of symptom onset. The primary efficacy end point was achievement of modified Thrombolysis in Cerebral Ischemia (mTICI) reperfusion scores of ≥2b within 3 EmboTrap passes as adjudicated by the core laboratory. The primary safety end point was a composite of symptomatic intracerebral hemorrhage and serious adverse device effects. Secondary end points included functional independence (modified Rankin Scale, 0-2) and all-cause mortality at 90 days. Results-Between October 2015 and February 2017, 227 patients were enrolled and treated with the EmboTrap device. The primary efficacy end point (mTICI ≥2b within 3 passes) was achieved in 80.2% (95% confidence interval, 74%.85% versus 56% performance goal criterion; P value, <0.0001), and mTICI 2c/3 was 65%. After all interventions, mTICI 2c/3 was achieved in 76%, and mTICI ≥2b was 92.5%. The rate of first pass (mTICI ≥2b following a single pass) was 51.5%. The primary safety end point composite rate of symptomatic intracerebral hemorrhage or serious adverse device effects was 5.3%. Functional independence and all-cause mortality at 90 days were 67% and 9%, respectively. Conclusions-The EmboTrap stent-retriever mechanical thrombectomy device demonstrated high rates of substantial reperfusion and functional independence in patients with acute ischemic stroke secondary to large-vessel occlusions.

Original languageEnglish
Pages (from-to)1107-1115
Number of pages9
JournalStroke
Volume49
Issue number5
DOIs
StatePublished - 2018

Keywords

  • Goals
  • Humans
  • Reperfusion
  • Stroke
  • Thrombectomy

Fingerprint