Skip to main navigation Skip to search Skip to main content

Post-fire axial load resistance of concrete-filled, double-skin tube (CFDST) stub columns

  • Thornton Tomasetti, Inc.

Research output: Contribution to specialist publicationArticle

Abstract

This technical note reports findings on a series of squash tests to investigate the effects of a significant fire loading history on the axial load strength of concrete-filled, double-skin tube (CFDST) stub columns. Axial loading tests were conducted on two stub columns that were previously subjected to the first 60 minutes of the standard ASTM E119 (ASTM, 2012) fire. Results were compared to the resistance of an identical virgin stub column. Comparisons indicated an average reduction of 28% in the axial load strength of stub columns when subjected to the mentioned fire loading history.

Original languageEnglish
Pages203-208
Number of pages6
Volume55
No4
Specialist publicationEngineering Journal
StatePublished - 2018

Keywords

  • ASTM E119
  • Axial strength
  • Double skin
  • Fire loading
  • Steel tube column

Fingerprint

Dive into the research topics of 'Post-fire axial load resistance of concrete-filled, double-skin tube (CFDST) stub columns'. Together they form a unique fingerprint.