Skip to main navigation Skip to search Skip to main content

Pilot intervention study of household ventilation and fine particulate matter concentrations in a low-income Urban Area, Dhaka, Bangladesh

  • Anne M. Weaver
  • , Shahana Parveen
  • , Doli Goswami
  • , Christina Crabtree-Ide
  • , Carole Rudra
  • , Jihnhee Yu
  • , Lina Mu
  • , Alicia M. Fry
  • , Iffat Sharmin
  • , Stephen P. Luby
  • , Pavani K. Ram
  • United States Environmental Protection Agency
  • SUNY Buffalo
  • International Centre for Diarrhoeal Disease Research Bangladesh
  • Centers for Disease Control and Prevention
  • Stanford University

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Fine particulate matter (PM2.5) is a risk factor for pneumonia; ventilation may be protective. We tested behavioral and structural ventilation interventions on indoorPM2.5 in Dhaka, Bangladesh.Werecruited 59 good ventilation (window or door in ≥ 3 walls) and 29 poor ventilation (no window, one door) homes. We monitored baseline indoor and outdoor PM2.5 for 48 hours. We asked all participants to increase ventilation behavior, including opening windows and doors, and operating fans. Where permitted, we installed windows in nine poor ventilation homes, then repeated PM2.5 monitoring. We estimated effects using linear mixed-effects models and conducted qualitative interviews regarding motivators and barriers to ventilation. Compared with poor ventilation homes, good ventilation homes were larger, their residents wealthier and less likely to use biomass fuel. In multivariable linear mixed-effects models, ventilation structures and opening a door or window were inversely associated with the number of hours PM2.5 concentrations exceeded 100 and 250 μg/m3. Outdoor air pollution was positively associated with the number of hours PM2.5 concentrations exceeded 100 and 250 μg/m3. Few homes accepted window installation, due to landlord refusal and fear of theft. Motivators for ventilation behavior included cooling of the home and sunlight; barriers included rain, outdoor odors or noise, theft risk, mosquito entry, and, for fan use, perceptions of wasting electricity or unavailability of electricity. We concluded that ventilation may reduce indoor PM2.5 concentrations but, there are barriers to increasing ventilation and, in areas with high ambient PM2.5 concentrations, indoor concentrations may remain above recommended levels.

Original languageEnglish
Pages (from-to)615-623
Number of pages9
JournalAmerican Journal of Tropical Medicine and Hygiene
Volume97
Issue number2
DOIs
StatePublished - 2017

Fingerprint

Dive into the research topics of 'Pilot intervention study of household ventilation and fine particulate matter concentrations in a low-income Urban Area, Dhaka, Bangladesh'. Together they form a unique fingerprint.

Cite this