Skip to main navigation Skip to search Skip to main content

Pharmacokinetics of ICG and HPPH-car for the detection of normal and tumor tissue using fluorescence, near-infrared reflectance imaging: A case study

  • Michael Gurfinkel
  • , Alan B. Thompson
  • , William Ralston
  • , Tamara L. Troy
  • , Ana L. Moore
  • , Thomas A. Moore
  • , J. Devens Gust
  • , Derreck Tatman
  • , Jeffery S. Reynolds
  • , Bruce Muggenburg
  • , Kristin Nikula
  • , Ravindra Pandey
  • , Ralf H. Mayer
  • , Daniel J. Hawrysz
  • , Eva M. Sevick-Muraca
  • Purdue University
  • Mallinckrodt Inc
  • Arizona State University
  • Lovelace Respiratory Research Institute
  • Texas A&M University

Research output: Contribution to journal › Article › peer-review

170 Scopus citations

Abstract

We present in vivo fluorescent, near-infrared (NIR), reflectance images of indocyanine green (ICG) and carotene-conjugated 2-devinyl-2-(1-hexyloxyethyl) pyropheophorbide (HPPH-car) to discriminate spontaneous canine adenocarcinoma from normal mammary tissue. Following intravenous administration of 1.0 mg kg-1 ICG or 0.3 mg kg-1 HPPH-car into the canine, a 25 mW, 778 nm or 70 mW, 660 nm laser diode beam, expanded by a diverging lens to approximately 4 cm in diameter, illuminated the surface of the mammary tissue. Successfully propagating to the tissue surface, ICG or HPPH-car fluorescence generated from within the tissue was collected by an image-intensified, charge-coupled device camera fitted with an 830 or 710 nm bandpass interference filter. Upon collecting time-dependent fluorescence images at the tissue surface overlying both normal and diseased tissue volumes, and fitting these images to a pharmacokinetic model describing the uptake (wash-in) and release (wash-out) of fluorescent dye, the pharmacokinetics of fluorescent dye was spatially determined. Mapping the fluorescence intensity owing to ICG indicates that the dye acts as a blood pool or blood persistent agent, for the model parameters show no difference in the ICG uptake rates between normal and diseased tissue regions. The wash-out of ICG was delayed for up to 72 h after intravenous injection in tissue volumes associated with disease, because ICG fluorescence was still detected in the diseased tissue 72 h after injection. In contrast, HPPH-car pharmacokinetics illustrated active uptake into diseased tissues, perhaps owing to the overexpression of LDL receptors associated with the malignant cells. HPPH-car fluorescence was not discernable after 24 h. This work illustrates the ability to monitor the pharmacokinetic delivery of NIR fluorescent dyes within tissue volumes as great as 0.5-1 cm from the tissue surface in order to differentiate normal from diseased tissue volumes on the basis of parameters obtained from the pharmacokinetic models.

Original languageEnglish
Pages (from-to)94-102
Number of pages9
JournalPhotochemistry and Photobiology
Volume72
Issue number1
DOIs
StatePublished - Jul 1 2000

Fingerprint

Dive into the research topics of 'Pharmacokinetics of ICG and HPPH-car for the detection of normal and tumor tissue using fluorescence, near-infrared reflectance imaging: A case study'. Together they form a unique fingerprint.

Cite this