Pharmacokinetics of ICG and HPPH-car for Detection of Normal and Tumor Tissue Using Fluorescence, Near-Infrared Continuous Wave Imaging

  • Michael Gurfinkel
  • , Alan B. Thompson
  • , William Ralston
  • , Tamara L. Troy
  • , Jeffery S. Reynolds
  • , Bruce Muggenberger
  • , Kristin Nikula
  • , Ravindra Pandey
  • , Ralf Mayer
  • , Daniel J. Hawrysz
  • , Eva M. Sevick-Muraca
  • Purdue University
  • Mallinckrodt Inc
  • Lovelace Respiratory Research Institute

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

We present in-vivo fluorescent, near-infrared, continuous wave images of indocyanine green (ICG) and carotene-conjugated 2-devinyl-2-(1-hexyloxyethyl) pyropheophorbide (HPPH-car) to discriminate spontaneous canine adenocarcinoma from normal mammary tissue. Following intravenous administration of 1.0 mg/kg ICG or 0.3 mg/kg HPPH-car into the canine, a 20-mW, 780-nm or 100-mW, 660-nm laser diode beam, expanded by a diverging lens to approximately 4 cm in diameter, illuminated the surface of the mammary tissue. Successfully propagating to the tissue surface, ICG or HPPH-car fluorescence generated from within the tissue was collected by an image-intensified, CCD camera fitted with an 830-nm or 710-nrn bandpass interference filter. Upon collecting time-dependent fluorescent images at the tissue surface overlying both normal and diseased tissue volumes and fitting these images to a pharmacokinetic model describing the uptake (wash-in) and release (wash-out) of fluorescent dye, the pharmacokinetics of fluorescent dye was spatially determined. Mapping the pharmacokinetic parameters for ICG indicates that the dye acts as a blood pool or blood persistent agent with enhanced passive uptake into or retention in diseased tissue regions presumably owing to "leaky"angiogenic vessels feeding the tumor. The wash-out of ICG was delayed for up to 72 hours after intravenous injection in tissue volumes associated with disease, for ICG fluorescence was still detected in the diseased tissue 72 hours post-injection. In contrast, HPPH-car pharmacokinetics illustrated active uptake into diseased tissues, perhaps owing to the over-expression of LDL receptors associated with the tumor endothelium. HPPH-car fluorescence was not discernable after 24 hours. This work illustrates the ability to monitor the pharmacokinetic delivery of near-infrared fluorescent dyes within tissue volumes as great as 2 cm from the tissue surface and to differentiate normal from diseased tissue volumes on the basis of parameters obtained from the pharmacokinetic models.

Original languageEnglish
Title of host publicationBiomedical Optical Spectroscopy and Diagnostics, BOSD 2000
PublisherOptica Publishing Group (formerly OSA)
Pages245-248
Number of pages4
ISBN (Electronic)155752632X
StatePublished - 2000
EventBiomedical Optical Spectroscopy and Diagnostics, BOSD 2000 - Miami Beach, United States
Duration: Apr 2 2000 → …

Publication series

NameOptics InfoBase Conference Papers
ISSN (Electronic)2162-2701

Conference

ConferenceBiomedical Optical Spectroscopy and Diagnostics, BOSD 2000
Country/TerritoryUnited States
CityMiami Beach
Period04/2/00 → …

Fingerprint

Dive into the research topics of 'Pharmacokinetics of ICG and HPPH-car for Detection of Normal and Tumor Tissue Using Fluorescence, Near-Infrared Continuous Wave Imaging'. Together they form a unique fingerprint.

Cite this