Skip to main navigation Skip to search Skip to main content

Phantom-based experimental validation of fast virtual deployment of self-expandable stents for cerebral aneurysms

  • Qianqian Zhang
  • , Zhuangyuan Meng
  • , Ying Zhang
  • , Kai Yao
  • , Jian Liu
  • , Yisen Zhang
  • , Linkai Jing
  • , Xinjian Yang
  • , Nikhil Paliwal
  • , Hui Meng
  • , Shengzhang Wang
  • Capital Medical University
  • Fudan University
  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Background: Endovascular intervention using a stent is a mainstream treatment for cerebral aneurysms. To assess the effect of intervention strategies on aneurysm hemodynamics, we have developed a fast virtual stenting (FVS) technique to simulate stent deployment in patient-specific aneurysms. However, quantitative validation of the FVS against experimental data has not been fully addressed. In this study, we performed in vitro analysis of a patient-specific model to illustrate the realism and usability of this novel FVS technique. Methods: We selected a patient-specific aneurysm and reproduced it in a manufactured realistic aneurismal phantom. Three numerical simulation models of the aneurysm with an Enterprise stent were constructed. Three models were constructed to obtain the stented aneurysms: a physical phantom scanned by micro-CT, fast virtual stenting technique and finite element method. The flow in the three models was simulated using a computational fluid dynamics software package, and the hemodynamics parameters for the three models were calculated and analyzed. Results: The computational hemodynamics in the patient-specific aneurysm of the three models resembled the very well. A qualitative comparison revealed high similarity in the wall shear stress, streamline, and velocity plane among the three different methods. Quantitative comparisons revealed that the difference ratios of the hemodynamic parameters were less than 10%, with the difference ratios for area average of wall shear stress in the aneurysm being very low. Conclusions: In conclusion, the results of the computational hemodynamics indicate that FVS is suitable for evaluation of the hemodynamic factors that affect treatment outcomes.

Original languageEnglish
Article number125
JournalBioMedical Engineering Online
Volume15
DOIs
StatePublished - Dec 28 2016

Fingerprint

Dive into the research topics of 'Phantom-based experimental validation of fast virtual deployment of self-expandable stents for cerebral aneurysms'. Together they form a unique fingerprint.

Cite this