Skip to main navigation Skip to search Skip to main content

Peri-implant tissue response of immediately loaded, threaded, HA-coated implants: 1-Year results

  • Kitichai Rungcharassaeng
  • , Jaime L. Lozada
  • , Joseph Y.K. Kan
  • , Jay S. Kim
  • , Wayne V. Campagni
  • , Carlos A. Munoz
  • Loma Linda University Health

Research output: Contribution to journalArticlepeer-review

45 Scopus citations

Abstract

Statement of problem. Although high success rates have been reported with immediately loaded implants, the peri-implant tissue response has not been well documented. Purpose. This study evaluated implant success and peri-implant tissue response of immediately loaded, threaded, hydroxyapatite (HA)-coated root-form implants supporting mandibular bar overdentures with opposing conventional maxillary complete dentures in humans. Material and methods. Five patients (3 men, 2 women; mean age 61 years) each received 4 HA-coated endosseous root-form implants in the interforaminal region in the mandible. The implants were rigidly splinted with a metal framework within 24 hours. The final EDS clip prosthesis was placed 1 to 2 weeks thereafter. The implants and peri-implant tissues were evaluated clinically and radiographically 0, 1, 3, 6, and 12 months after prosthesis placement. Data were analyzed with a repeated measures 1-way analysis of variance (P<.05). Results. All implants were stable at the end of the observation period (mean Periotest value = -5.9 ± 1.4). No peri-implant radiolucencies were noted, and no implants were lost. The mean marginal bone changes were -0.42 ± 0.34, -0.84 ± 0.55, -1.14 ± 0.80, and -1.16 ± 0.89 mm at the 1-, 3-, 6-, and 12-month follow-ups, respectively (P<.001). Significant declines in the rates of marginal bone changes at each time interval were noted (P<.001). In addition, there were significant decreases in probing depth (P<.001) and plaque index (P<.001) but no significant difference in the frequency of bleeding upon probing (P=.64). Conclusion. Within the limitations of this study, the peri-implant tissue response of immediately loaded, HA-coated implants was favorable and comparable to that of conventional, delayed-loaded implants after 1 year.

Original languageEnglish
Pages (from-to)173-181
Number of pages9
JournalJournal of Prosthetic Dentistry
Volume87
Issue number2
DOIs
StatePublished - 2002

Fingerprint

Dive into the research topics of 'Peri-implant tissue response of immediately loaded, threaded, HA-coated implants: 1-Year results'. Together they form a unique fingerprint.

Cite this