Performance of a seismically isolated bridge under near-fault earthquake ground motions

  • LENDIS Corporation
  • SUNY Buffalo
  • China Engineering Consultants, Inc.
  • National Taiwan University

Research output: Contribution to journalArticlepeer-review

140 Scopus citations

Abstract

A bridge with lead-rubber seismic isolation bearings was field-tested to evaluate the assumptions and uncertainties in the design and construction. A numerical model was established based on satisfactory predictions of the dynamic characteristics under ambient vibration, free vibration tests, and the seismic performance under the 1022 Gia-Yi earthquake. Parametric studies of this model, under simulated near-fault ground motions, were carried out to investigate the near-fault effect. Two types of velocity pulse that characterize the near-fault effect were investigated. Results revealed amplified seismic response when the pulse period was close to the effective period. The response amplification by a longer period pulse was not consistent for the two pulse types. Additional observations included the ratio of dissipated energy by the lead-rubber bearings to the total input energy, which could be influenced by the near-fault effect. Variation of the near-fault effect due to a change of structural parameters was studied to provide information on possible mitigation strategy.

Original languageEnglish
Pages (from-to)861-868
Number of pages8
JournalJournal of Structural Engineering
Volume130
Issue number6
DOIs
StatePublished - Jun 2004

Keywords

  • Bearing capacity
  • Bridges
  • Earthquakes
  • Isolation
  • Lead
  • Rubber

Fingerprint

Dive into the research topics of 'Performance of a seismically isolated bridge under near-fault earthquake ground motions'. Together they form a unique fingerprint.