T1 - Performance evaluation and comparison of two triple-nuclear RF resonators for 1H/19F/31PMR imaging at 9.4T
AU - Du, Feng
AU - Liu, Shengping
AU - Li, Nan
AU - Liu, Congcong
AU - Chen, Qiaoyan
AU - Zhang, Shuai
AU - Wang, Haifeng
AU - Zhang, Xiaoliang
AU - Li, Ye
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/8
Y1 - 2019/8
N2 - Radio frequency (RF) coils are critical devices in magnetic resonance (MR) systems for transmitting and receiving magnetic resonance signals. However, the required high operating frequency at ultrahigh magnetic fields makes the design of highly efficient radio frequency (RF) transmit or receive coils technically challenging. This is particularly true in the double-tuned or triple-tuned RF coils usually required in heteronuclear MRI and MRS where multiple nuclei, such as 1H, 19F, and 31P, are involved. The performance of RF coils is a critically important factor for realizing the high sensitivity provided by ultrahigh magnetic fields to contribute towards the advancement of a novel human in vivo application at 9.4T. In this work, two different configurations of novel triple-nuclear (1H/19F/31P) RF resonators were proposed for the ultrahigh field 9.4T applications. We also reported on the design and construction, and a field-circuit co-simulation was used to obtain the S-parameters, B1+ field and specific absorption rate (SAR) distributions to evaluate and compare their performance. And the characteristics and advantages of the proposed two different configurations of triple-nuclear RF resonators in the applications of 1H/19F/31P at ultrahigh magnetic field were investigated.
AB - Radio frequency (RF) coils are critical devices in magnetic resonance (MR) systems for transmitting and receiving magnetic resonance signals. However, the required high operating frequency at ultrahigh magnetic fields makes the design of highly efficient radio frequency (RF) transmit or receive coils technically challenging. This is particularly true in the double-tuned or triple-tuned RF coils usually required in heteronuclear MRI and MRS where multiple nuclei, such as 1H, 19F, and 31P, are involved. The performance of RF coils is a critically important factor for realizing the high sensitivity provided by ultrahigh magnetic fields to contribute towards the advancement of a novel human in vivo application at 9.4T. In this work, two different configurations of novel triple-nuclear (1H/19F/31P) RF resonators were proposed for the ultrahigh field 9.4T applications. We also reported on the design and construction, and a field-circuit co-simulation was used to obtain the S-parameters, B1+ field and specific absorption rate (SAR) distributions to evaluate and compare their performance. And the characteristics and advantages of the proposed two different configurations of triple-nuclear RF resonators in the applications of 1H/19F/31P at ultrahigh magnetic field were investigated.
UR - https://www.scopus.com/pages/publications/85083316227
U2 - 10.1109/RCAR47638.2019.9044102
DO - 10.1109/RCAR47638.2019.9044102
M3 - Conference contribution
AN - SCOPUS:85083316227
T3 - 2019 IEEE International Conference on Real-Time Computing and Robotics, RCAR 2019
SP - 598
EP - 603
BT - 2019 IEEE International Conference on Real-Time Computing and Robotics, RCAR 2019
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2019 IEEE International Conference on Real-Time Computing and Robotics, RCAR 2019
Y2 - 4 August 2019 through 9 August 2019
ER -