Skip to main navigation Skip to search Skip to main content

Performance Characteristics of Photoacoustic Imaging Probes with Varying Frequencies and Light-delivery Schemes

  • Laurie J. Rich
  • , Sarah R. Chamberlain
  • , Daniela R. Falcone
  • , Robert Bruce
  • , Andrew Heinmiller
  • , Jun Xia
  • , Mukund Seshadri
  • Roswell Park Cancer Institute
  • State University of New York System
  • FUJIFILM VisualSonics, Inc.

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Photoacoustic imaging (PAI) is an emerging biomedical imaging technique that utilizes a combination of light and ultrasound to detect photoabsorbers embedded within tissues. While the clinical utility of PAI has been widely explored for several applications, limitations in light penetration and detector sensitivity have restricted these studies to mostly superficial sites. Given the importance of PA signal generation and detection on light delivery and ultrasound detector frequency, there is an ongoing effort to optimize these parameters to enhance photoabsorber detection at increased depths. With this in mind, in this study we examined performance benchmarks of a commercially available PAI/ultrasound linear array system when using different imaging frequencies and light delivery schemes. A modified light fiber jacket providing focused light delivery (FLD) at the center of the probe was compared with the built-in fiber optics lining the length of the probe. Studies were performed in vitro to compare performance characteristics such as imaging resolution, maximum imaging depth, and sensitivity to varying hematocrit concentration for each frequency and light delivery method. Monte Carlo simulations of each light delivery method revealed increased light penetration with FLD. In tissue-mimicking phantoms, vascular channels used to simulate blood vessels could be visualized at a depth of 2.4 cm when lowering imaging frequency and utilizing FLD. Imaging at lower frequencies with FLD also enabled enhanced detection of varying hematocrit concentration levels at increased depths, although lateral imaging resolution was reduced. Finally, a proof of concept in vivo probe comparison study in a mouse tumor model provided supportive evidence of our in vitro results. Collectively, our findings show that adjusting imaging frequency and applying FLD can be a straightforward approach for improving PAI performance.

Original languageEnglish
Pages (from-to)319-335
Number of pages17
JournalUltrasonic Imaging
Volume41
Issue number6
DOIs
StatePublished - Nov 1 2019

Keywords

  • head and neck cancers
  • linear array
  • phantoms
  • photoacoustic imaging
  • ultrasound

Fingerprint

Dive into the research topics of 'Performance Characteristics of Photoacoustic Imaging Probes with Varying Frequencies and Light-delivery Schemes'. Together they form a unique fingerprint.

Cite this