Skip to main navigation Skip to search Skip to main content

Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease

  • Kelsey N. Sommer
  • , Lauren M. Shepard
  • , Dimitrios Mitsouras
  • , Vijay Iyer
  • , Erin Angel
  • , Michael F. Wilson
  • , Frank J. Rybicki
  • , Kanako Kunishima Kumamaru
  • , Umesh C. Sharma
  • , Abhinay Reddy
  • , Shinichiro Fujimoto
  • , Ciprian N. Ionita
  • SUNY Buffalo
  • University of California at San Francisco
  • Canon Inc.
  • University of Cincinnati
  • Juntendo University

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Background: 3D printed patient-specific coronary models have the ability to enable repeatable benchtop experiments under controlled blood flow conditions. This approach can be applied to CT-derived patient geometries to emulate coronary flow and related parameters such as Fractional Flow Reserve (FFR). Methods: This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements. Fifty-two patients with a clinical indication for I-FFR underwent a research Coronary CT Angiography (CCTA) prior to catheterization. CT images were used to measure CT-FFR and to generate patient-specific 3D printed models of the aortic root and three main coronary arteries. Each patient-specific model was connected to a programmable pulsatile pump and benchtop FFR (B-FFR) was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. B-FFR was measured for two coronary outflow rates ('normal', 250 ml min-1; and 'hyperemic', 500 ml min-1) by adjusting the model's distal coronary resistance. Results: Pearson correlations and ROC AUC were calculated using invasive I-FFR as reference. The Pearson correlation factor of CT-FFR and B-FFR-500 was 0.75 and 0.71, respectively. Areas under the ROCs for CT-FFR and B-FFR-500 were 0.80 (95%CI: 0.70-0.87) and 0.81 (95%CI: 0.64-0.91) respectively. Conclusion: Benchtop flow simulations with 3D printed models provide the capability to measure pressure changes at any location in the model, for ultimately emulating the FFR at several simulated physiological blood flow conditions. Clinical Trial Registration: http://clinicaltrials.gov/show/NCT03149042

Original languageEnglish
Article number045007
JournalBiomedical Physics and Engineering Express
Volume6
Issue number4
DOIs
StatePublished - Jul 2020

Keywords

  • 3D printing
  • CT-FFR
  • coronary CTA
  • coronary artery disease

Fingerprint

Dive into the research topics of 'Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease'. Together they form a unique fingerprint.

Cite this