Abstract
A parametric finite element analysis study was carried out on slotted rectangular and square hollow structural section (HSS) tension connections without welding at the end of the gusset plate for different weld length ratio, slot orientation, weld size and level of HSS corner strength compared to its flat segment. Finite element models for the parametric study were developed and validated against test results of the connection with the tube slotted. The modified weld length ratio was found to be a better parameter than the modified eccentricity ratio in characterizing the net section efficiency of a slotted HSS tension member when the weld length is short. Improvements to provisions in CSA-S16-01 and ANSI/AISC-360-05 for slotted tubular tension connections were proposed based on results of the study.
| Original language | English |
|---|---|
| Pages (from-to) | 611-621 |
| Number of pages | 11 |
| Journal | Journal of Constructional Steel Research |
| Volume | 65 |
| Issue number | 3 |
| DOIs | |
| State | Published - Mar 2009 |
Keywords
- Connections
- Finite element analyses
- Gusset plates
- Hollow structural sections
- Shear lag
- Slotted
- Tubes
- Welded
Fingerprint
Dive into the research topics of 'Parametric finite element study on slotted rectangular and square HSS tension connections'. Together they form a unique fingerprint.Cite this