Overcoming x-ray tube small focal spot output limitations for high resolution region of interest imaging

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

6 Scopus citations

Abstract

We investigate methods to increase x-ray tube output to enable improved quantum image quality with a higher generalized-NEQ (GNEQ) while maintaining a small focal-spot size for the new high-resolution Micro-angiographic Fluoroscope (MAF) Region of Interest (ROI) imaging system. Rather than using a larger focal spot to increase tubeloading capacity with degraded resolution, we evaluated separately or in combination three methods to increase tube output: 1) reducing the anode angle and lengthening the filament to maintain a constant effective small focal-spot size, 2) using the standard medium focal spot viewed from a direction on the anode side of the field and 3) increasing the frame rate (frames/second) in combination with temporal filter. The GNEQ was compared for the MAF for the small focal-spot at the central axis, and for the medium focal-spot with a higher output on the anode side as well as for the small focal spot with different temporal recursive filtering weights. A net output increase of about 4.0 times could be achieved with a 2-degree anode angle (without the added filtration) and a 4 times longer filament compared to that of the standard 8-degree target. The GNEQ was also increased for the medium focal-spot due to its higher output capacity and for the temporally filtered higher frame rate. Thus higher tube output, while maintaining a small effective focal-spot, should be achievable using one or more of the three methods described with only small modifications of standard x-ray tube geometry.

Original languageEnglish
Title of host publicationMedical Imaging 2012
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2012
EventMedical Imaging 2012: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 5 2012Feb 8 2012

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume8313
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2012: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period02/5/1202/8/12

Keywords

  • CNR
  • EIGI
  • Focal spot
  • GNEQ
  • MAF
  • MTF
  • NEQ
  • NNPS
  • ROI
  • X-ray tube

Fingerprint

Dive into the research topics of 'Overcoming x-ray tube small focal spot output limitations for high resolution region of interest imaging'. Together they form a unique fingerprint.

Cite this