Skip to main navigation Skip to search Skip to main content

Optical assessment of soft contact lens edge-thickness

  • Patrice Tankam
  • , Jungeun Won
  • , Cristina Canavesi
  • , Ian Cox
  • , Jannick P. Rolland
  • University of Rochester
  • LighTopTech Corp.
  • IGC Consulting

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Purpose. To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-μm imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm. Conclusions. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCMin the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.

Original languageEnglish
Pages (from-to)987-996
Number of pages10
JournalOptometry and Vision Science
Volume93
Issue number8
DOIs
StatePublished - Jul 26 2016

Keywords

  • Edge-thickness
  • Microscopy
  • Optical coherence tomography
  • Optical metrology
  • Soft contact lens

Fingerprint

Dive into the research topics of 'Optical assessment of soft contact lens edge-thickness'. Together they form a unique fingerprint.

Cite this