Skip to main navigation Skip to search Skip to main content

One-year safety and effectiveness of the Alto abdominal stent graft in the ELEVATE IDE trial

  • Sean P. Lyden
  • , D. Christopher Metzger
  • , Steve Henao
  • , Sonya Noor
  • , Andrew Barleben
  • , John P. Henretta
  • , Levester Kirksey
  • Cleveland Clinic Foundation
  • Ballad Health
  • Presbyterian Healthcare Services, New Mexico
  • University of California at San Diego
  • Mission Hospital

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Objective: This study reports the results of a prospective, multicenter trial designed to evaluate the safety and effectiveness of the polymer based Endologix Alto Stent Graft System in treating abdominal aortic aneurysms (AAAs), with sealing 7 mm below the top of the fabric in aortic neck diameters from 16 to 30 mm. Methods: Seventy-five patients were treated with Alto devices between March 2017 and February 2018 in 16 centers in the United States for infrarenal AAAs (max diameter ≥5.0 cm in diameter or size increase by 0.5 cm in 6 months or diameter ≥1.5 times the adjacent normal aorta). Patients were followed for 30 days, 6 months, and 1 year by clinical evaluation and computed tomography and abdominal x-ray imaging. Treatment success was defined as technical success and freedom from AAA enlargement, migration, type I or III endoleak, AAA rupture or surgical conversion, stent graft stenosis, occlusion, kink, thromboembolic events, and stent fracture attributable to the device requiring secondary intervention through 12 months. Preoperative characteristics, perioperative variables, follow-up clinical evaluations, and radiographic examination results through the first 1 year were analyzed. Results: The mean patient age was 73 years, with 93% of patients being male. The 30-day major adverse event rate was 5.3%. At 1 year, the primary endpoint was met with a treatment success rate of 96.7%. Through 1-year post-treatment, all-cause mortality was 4.0%. No AAA-related mortality occurred. AAA enlargement was 1.6%, type I endoleak rate was 1.4%, with 100% freedom from type III endoleaks, device migration, device fracture, stent occlusion, or AAA rupture. The device-related secondary intervention rate was 2.7%. Conclusions: This prospective study demonstrates the Endologix Alto is safe and effective in treating AAAs with appropriate anatomy at 1 year. The safety endpoint is met by a 5.3% 30-day major adverse event rate, whereas the effectiveness endpoint is met by a treatment success rate of 96%.

Original languageEnglish
Pages (from-to)446-453.e3
JournalJournal of Vascular Surgery
Volume77
Issue number2
DOIs
StatePublished - Feb 2023

Keywords

  • Abdominal aortic aneurysm (AAA)
  • Alto
  • ELEVATE
  • Endovascular aneurysm repair (EVAR)
  • Ovation

Fingerprint

Dive into the research topics of 'One-year safety and effectiveness of the Alto abdominal stent graft in the ELEVATE IDE trial'. Together they form a unique fingerprint.

Cite this