New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

22 Scopus citations

Abstract

New cone-beam computed tomographic (CBCT) mammography system designs are presented where the detectors provide high spatial resolution, high sensitivity, low noise, wide dynamic range, negligible lag and high frame rates similar to features required for high performance fluoroscopy detectors. The x-ray detectors consist of a phosphor coupled by a fiber-optic taper to either a high gain image light amplifier (LA) then CCD camera or to an electron multiplying CCD. When a square-array of such detectors is used, a field-of-view (FOV) to 20 × 20 cm can be obtained where the images have pixel-resolution of 100 urn or better. To achieve practical CBCT mammography scan-times, 30 fps may be acquired with quantum limited (noise free) performance below 0.2 μR detector exposure per frame. Because of the flexible voltage controlled gain of the LA's and EMCCDs, large detector dynamic range is also achievable. Features of such detector systems with arrays of either generation 2 (Gen 2) or 3 (Gen 3) LAs optically coupled to CCD cameras or arrays of EMCCDs coupled directly are compared. Quantum accounting analysis is done for a variety of such designs where either the lowest number of information carriers off the LA photo-cathode or electrons released in the EMCCDs per x-ray absorbed in the phosphor are large enough to imply no quantum sink for the design. These new LA- or EMCCD-based systems could lead to vastly improved CBCT mammography, ROI-CT, or fluoroscopy performance compared to systems using flat panels.

Original languageEnglish
Title of host publicationMedical Imaging 2006
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2006
EventMedical Imaging 2006: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 12 2006Feb 16 2006

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6142 II
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2006: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period02/12/0602/16/06

Keywords

  • CT
  • Cone beam computed tomography
  • Detector arrays
  • Detector mosaic
  • Electron multiplying CCD
  • Fluoroscopy
  • Light amplifiers
  • Mammography
  • Quantum accounting
  • X-ray detectors

Fingerprint

Dive into the research topics of 'New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy'. Together they form a unique fingerprint.

Cite this