Abstract
BACKGROUND.: Despite their clinical importance, clinical routine tests to detect anti-endothelial cell antibodies (AECA) in organ transplantation have not been readily available. This multicenter prospective kidney transplantation trial evaluates the efficacy of a novel endothelial cell crossmatch (ECXM) test to detect donor-reactive AECA associated with kidney allograft rejection. METHODS.: Pretransplant serum samples from 147 patients were tested for AECA by a novel flow cytometric crossmatch technique (XM-ONE) using peripheral blood endothelial progenitor cells as targets. Patient enrolment was based on acceptance for transplantation determined by donor lymphocyte crossmatch results. RESULTS.: Donor-reactive AECA were found in 35 of 147 (24%) patients. A significantly higher proportion of patients with a positive ECXM had rejections (16 of 35, 46%) during the follow-up of at least 3 months compared with those without AECA (13 of 112, 12%; P<0.00005). Both IgG and IgM AECAs were associated with graft rejections. Mean serum creatinine levels were significantly higher in patients with a positive ECXM test at 3 and 6 months posttransplant. CONCLUSIONS.: XM-ONE is quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte crossmatches.
| Original language | English |
|---|---|
| Pages (from-to) | 549-556 |
| Number of pages | 8 |
| Journal | Transplantation |
| Volume | 87 |
| Issue number | 4 |
| DOIs | |
| State | Published - Feb 27 2009 |
Keywords
- Alloantibodies
- Crossmatch
- Endothelium
- Histocompatibility
- Humoral allograft rejection
- Kidney transplantation
Fingerprint
Dive into the research topics of 'Multicenter evaluation of a novel endothelial cell crossmatch test in kidney transplantation'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver