TY - JOUR
T1 - Multicenter early United States feasibility study and periprocedural safety of LVIS EVO for the treatment of unruptured intracranial aneurysms
AU - Kayan, Yasha
AU - Delgado Almandoz, Josser E.
AU - Copelan, Alexander
AU - Matouk, Charles
AU - Chaudry, M. Imran
AU - Altschul, David
AU - Essibayi, Muhammed Amir
AU - Goren, Oded
AU - Yim, Benjamin
AU - Tsappidi, Sam
AU - Zhang, Yi Jonathan
AU - Hui, Ferdinand K.
AU - Samaniego, Edgar A.
AU - Gudino, Andres
AU - Siddiqui, Adnan
AU - Jaikumar, Vinay
AU - Puri, Ajit S.
AU - Kühn, Anna Luisa
AU - Singh, Jasmeet
AU - Ringer, Andrew
AU - Hanel, Ricardo A.
AU - De Toledo, Otavio Frederico
AU - Dabus, Guilherme
AU - Gooch, M. Reid
AU - Sizdahkhani, Saman
AU - Field, Nicholas C.
AU - Paul, Alexandra R.
N1 - Publisher Copyright:
© Author(s) (or their employer(s)) 2024.
PY - 2024/6/21
Y1 - 2024/6/21
N2 - Background Stent development has focused recently on low-profile, self-expandable stents compatible with 0.0165 inch microcatheters. The LVIS EVO is the second-generation version of the Low-Profile Visualized Intraluminal Support (LVIS) with improved visibility and resheathability. The LVIS EVO underwent a limited premarket release (PMR) in December 2023. This study aims to report the early safety and feasibility experience with the LVIS EVO stent for the treatment of intracranial aneurysms in the United States (US). Methods This was a multicenter, retrospective, observational study evaluating patients who underwent treatment of an intracranial aneurysm with an LVIS EVO stent after the limited PMR. All physicians who had placed an LVIS EVO stent were asked to input their cases after institutional review board approval was obtained. The data were then sent to a single center for analysis. Any patient aged 18 years or older who underwent treatment of an intracranial aneurysm with a LVIS EVO stent in the US was included from the initial PMR in December 2023 until April 2024. Patient age (or ≤90 years old), sex, preoperative modified Rankin Scale (mRS), aneurysm location, aneurysm measurements, and information about preoperative antiplatelet management were all collected. Data on periprocedural complications, 30-day mortality, discharge mRS, and length of stay were also collected. Results Some 53 patients with 55 aneurysms underwent treatment with the LVIS EVO stent at 15 institutions. All aneurysms were unruptured. The most common location was the anterior communicating artery (35%) followed by the middle cerebral artery bifurcation (31%). All patients were on dual antiplatelet therapy. The average aneurysm size was 5.2 mm with a neck size of 3.7 mm. The smallest distal parent vessel size was 1.2 mm and 36% of stents were deployed in distal parent vessels <2 mm. All (100%) cases had successful deployment and the stent was repositioned in 10% of cases. A single stent was utilized in 91% of cases. Coils were placed in 48 cases (87.2%) and a microcatheter was jailed in 98% of those cases. Immediate Raymond Roy (RR) Class I occlusion was obtained in 33%, Class II in 22%, Class IIIa in 37%, and Class IIIb in 8% of cases. There were no delayed thromboembolic or hemorrhagic complications. Conclusions The LVIS EVO is a braided, self-expanding, retrievable stent with enhanced visibility and smaller cell size. The drawn filled tube (DFT) technology results in improved visibility of the stent, allowing for more controlled stent positioning and visualization of vessel wall apposition. All cases in our series had complete neck coverage and good wall apposition. There were no thromboembolic or hemorrhagic complications.
AB - Background Stent development has focused recently on low-profile, self-expandable stents compatible with 0.0165 inch microcatheters. The LVIS EVO is the second-generation version of the Low-Profile Visualized Intraluminal Support (LVIS) with improved visibility and resheathability. The LVIS EVO underwent a limited premarket release (PMR) in December 2023. This study aims to report the early safety and feasibility experience with the LVIS EVO stent for the treatment of intracranial aneurysms in the United States (US). Methods This was a multicenter, retrospective, observational study evaluating patients who underwent treatment of an intracranial aneurysm with an LVIS EVO stent after the limited PMR. All physicians who had placed an LVIS EVO stent were asked to input their cases after institutional review board approval was obtained. The data were then sent to a single center for analysis. Any patient aged 18 years or older who underwent treatment of an intracranial aneurysm with a LVIS EVO stent in the US was included from the initial PMR in December 2023 until April 2024. Patient age (or ≤90 years old), sex, preoperative modified Rankin Scale (mRS), aneurysm location, aneurysm measurements, and information about preoperative antiplatelet management were all collected. Data on periprocedural complications, 30-day mortality, discharge mRS, and length of stay were also collected. Results Some 53 patients with 55 aneurysms underwent treatment with the LVIS EVO stent at 15 institutions. All aneurysms were unruptured. The most common location was the anterior communicating artery (35%) followed by the middle cerebral artery bifurcation (31%). All patients were on dual antiplatelet therapy. The average aneurysm size was 5.2 mm with a neck size of 3.7 mm. The smallest distal parent vessel size was 1.2 mm and 36% of stents were deployed in distal parent vessels <2 mm. All (100%) cases had successful deployment and the stent was repositioned in 10% of cases. A single stent was utilized in 91% of cases. Coils were placed in 48 cases (87.2%) and a microcatheter was jailed in 98% of those cases. Immediate Raymond Roy (RR) Class I occlusion was obtained in 33%, Class II in 22%, Class IIIa in 37%, and Class IIIb in 8% of cases. There were no delayed thromboembolic or hemorrhagic complications. Conclusions The LVIS EVO is a braided, self-expanding, retrievable stent with enhanced visibility and smaller cell size. The drawn filled tube (DFT) technology results in improved visibility of the stent, allowing for more controlled stent positioning and visualization of vessel wall apposition. All cases in our series had complete neck coverage and good wall apposition. There were no thromboembolic or hemorrhagic complications.
KW - Aneurysm
KW - Coil
KW - Device
KW - Stent
UR - https://www.scopus.com/pages/publications/85196902786
U2 - 10.1136/jnis-2024-021900
DO - 10.1136/jnis-2024-021900
M3 - Article
C2 - 38906689
AN - SCOPUS:85196902786
SN - 1759-8478
VL - 17
JO - Journal of NeuroInterventional Surgery
JF - Journal of NeuroInterventional Surgery
IS - 4
ER -