Skip to main navigation Skip to search Skip to main content

Multicenter comparative analysis of FRED-X, pipeline shield, and surpass evolve in treating intracranial aneurysms

  • Joanna M. Roy
  • , Basel Musmar
  • , Spyridon Karadimas
  • , Matthews Lan
  • , Sravanthi Koduri
  • , Arbaz Momin
  • , Alana McNulty
  • , Alexandra Paul
  • , Yi Zhang
  • , Ajit S. Puri
  • , Jasmeet Singh
  • , Anna Luisa Kuhn
  • , Vinay Jaikumar
  • , Jaims Lim
  • , Elad Levy
  • , M. Reid Gooch
  • , Pascal Jabbour
  • , Robert H. Rosenwasser
  • , Stavropoula I. Tjoumakaris
  • Thomas Jefferson University
  • Albany Medical College
  • Queens University Medical Group
  • University of Massachusetts Boston
  • SUNY Buffalo

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Background: In recent years, newer flow diverters have been developed with surface modification and varying wire densities. Our study evaluated outcomes among three newer generation flow diverter devices, FRED-X, PED Shield and Surpass Evolve. Methods: This was a retrospective study of patients from five participating institutions across the United States. Patients who underwent flow diversion of intracranial aneurysms using the FRED-X, PED Shield or Surpass Evolve between February 2022 and September 2024 were included. Outcomes of interest were technical success, angiographic occlusion and in-stent stenosis (ISS). Results: Among 447 patients with 452 aneurysms, adjunct device use was highest with Surpass Evolve (36.4%) versus PED Shield (15.7%) and FRED-X (6.4%) (p < .001). Good wall apposition after angioplasty/stenting was most frequent with Surpass Evolve (32.3%) versus PED Shield (13.7%) and FRED-X (4.5%) (p < .001). At six months, complete occlusion was achieved in 69.3% (PED Shield), 63.6% (FRED-X), and 58% (Surpass Evolve) (p = .254). ISS rates were comparable at six months (p = .826). At 12 months, complete occlusion was observed in 78.9% of PED Shield, 68.4% of FRED-X, and 64.5% of Surpass Evolve aneurysms. Most ISS cases at 12 months were mild. Kaplan-Meier analysis showed no significant difference in occlusion rates (p = .914). Conclusions: Flow diversion using FRED-X, PED Shield and Surpass Evolve resulted in comparable rates of angiographic occlusion and ISS. However, adjunctive devices were more commonly needed with Surpass Evolve.

Original languageEnglish
Article number15910199251384687
JournalInterventional Neuroradiology
DOIs
StateAccepted/In press - 2025

Keywords

  • Aneurysm
  • angiographic occlusion
  • flow diversion
  • surface modification

Fingerprint

Dive into the research topics of 'Multicenter comparative analysis of FRED-X, pipeline shield, and surpass evolve in treating intracranial aneurysms'. Together they form a unique fingerprint.

Cite this