Multi-resolution storage in a PACS archive

  • The University of Chicago
  • Lockheed Martin

Research output: Contribution to journalConference articlepeer-review

4 Scopus citations

Abstract

Many retrievals ofimages from a PACS archive do not require the fill spatial resolution at which the images were originally acquired. Savings in retrieval times could be realized if images were retrieved at the lower resolution required for each display need. A PACS archive was constructed wherein images are stored and may be retrieved at lower than the originally-acquired resolution. Incoming images from the modality devices are minified by successive factors oftwo, down to 128 x 128. A DICOM extended private attribute was defined which enabled the reduced resolution images to be retrieved with a modified DICOM move requests. The reduced resolution images can be received by a standard DICOM workstation without the need for special workstation software. Multi-resolution storage requires approximately 30% more space. This additional media cost is deemed acceptable for this archive, in which data are stored on low cost magnetic tape.

Original languageEnglish
Pages (from-to)39-46
Number of pages8
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume3035
DOIs
StatePublished - May 22 1997
EventMedical Imaging 1997: PACS Design and Evaluation: Engineering and Clinical Issues - Newport Beach, United States
Duration: Feb 22 1997Feb 28 1997