Skip to main navigation Skip to search Skip to main content

Modified throughput ninhydrin method for the qualitative assessment of dietary protein absorption in pig plasma

  • Kateryna Pierzynowska
  • , Kamil Zaworski
  • , Piotr Wychowanski
  • , Janine Donaldson
  • , Jarosław Wolinski
  • , Drucy Borowitz
  • , Robert Gallotto
  • , Stefan Pierzynowski
  • Lund University
  • The Kielanowski Institute of Animal Physiology and Nutrition of the Polish Academy of Sciences
  • Anagram Therapeutics Inc
  • Anara AB
  • Fondazione Policlinico Universitario A. Gemelli IRCCS
  • University of the Witwatersrand
  • Medical University of Lublin

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Protein maldigestion and malabsorption lead to malnutrition and are a feature of exocrine pancreatic insufficiency (EPI). Although it is the current standard, measurement of nitrogen in stool to assess protease activity is indirect. Up to 80% of hydrolysed proteins appear in blood in the form of peptides, so we developed a method to measure peptide-derived amino acids in plasma as a relevant measure of proteolysis, verified its accuracy, precision, and linearity, and validated it in a porcine model. We modified a ninhydrin method. Large proteins were eliminated from plasma with 10 kDa-cut-off centrifugal filters. Free and total amino acids were measured in permeate before and after its hydrolysis. Peptide-derived amino acids were quantified by subtracting free amino acids from total amino acids. We verified the method in vitro and by comparing results in healthy and EPI pigs. The accuracy of the analysis was close to 100%, with excellent precision (mean relative standard deviation for low, medium, and high amino acid levels ¼ 0.88%) and with stringent linearity (r2 ¼ 0.986, %RE ¼ 5.23). The high-throughput ninhydrin method detected levels of peptide-derived amino acids in vivo with maximal changes seen approximately 2 hours postprandially in young pigs. The AUC and Cmax were significantly higher in healthy compared to EPI pigs (P ¼ .0026 and P ¼ .0037, respectively). The high-throughput ninhydrin method is a sensitive, reliable, and practical method for the estimation of dietary peptide-derived amino acids. This assay endpoint could serve as a direct biomarker of protein digestion and absorption.

Original languageEnglish
Article numberbpae078
JournalBiology Methods and Protocols
Volume9
Issue number1
DOIs
StatePublished - 2024

Keywords

  • EPI pigs
  • healthy pigs
  • method
  • peptide absorption
  • validation

Fingerprint

Dive into the research topics of 'Modified throughput ninhydrin method for the qualitative assessment of dietary protein absorption in pig plasma'. Together they form a unique fingerprint.

Cite this