Skip to main navigation Skip to search Skip to main content

Mini-augmented glenoid baseplate and mini-humeral tray reverse total shoulder arthroplasty implant comparisons: two-year clinical outcomes

  • Ryan Krupp
  • , Christopher O’Grady
  • , Brian Werner
  • , J. Michael Wiater
  • , John Nyland
  • , Thomas Duquin
  • Norton Orthopedic Institute
  • Andrews Research and Education Foundation
  • University of Virginia
  • Corewell Health East William Beaumont University Hospital

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background: Augmented glenoid baseplate and offset humeral tray reverse total shoulder arthroplasty (RTSA) implants may decrease the mechanical impingement that creates scapular notching and improve shoulder function. This study evaluated the clinical efficacy of three different RTSA glenoid baseplate and offset humeral tray combinations for patient-reported shoulder function, pain and instability, radiographic imaging evidence of glenoid baseplate or humeral stem subsidence and migration, bony changes associated with implant loosening, and scapular notching over the initial 2 years post-RTSA. Primary outcomes included active shoulder mobility, perceived function, pain, instability, scapular notching, and implant survival. Methods: Sixty-seven patients from 6 research sites received one of three different glenoid baseplate and humeral tray combinations. Group 1 (n = 21) received a mini-augmented glenoid baseplate with a standard humeral tray; Group 2 (n = 23) received a standard glenoid baseplate and a mini-humeral tray with 3 trunnion offset options; Group 3 (n = 23) received both a mini-augmented glenoid baseplate and a mini-humeral tray with 3 trunnion offset options. Subjects underwent radiologic evaluation, completed the ASES scale, the EQ-5D-5L quality of life scale, VAS shoulder pain and instability questions, and active shoulder mobility measurements pre-operatively, and 6-weeks, 6-months, 1–2 years post-RTSA. Results: Improved active shoulder mobility, quality of life, perceived function, decreased shoulder pain and instability, excellent implant survival and minimal scapular notching were observed for all groups. Group 3 had better overall active shoulder mobility than the other groups and better perceived function than Group 1. Conclusion: The group that received the mini-augmented glenoid baseplate and mini-humeral tray combination had better overall active shoulder flexion, external rotation at 90° abduction, and internal rotation. This group also had better perceived shoulder function compared to the group that received a mini-augmented glenoid baseplate with a standard humeral tray.

Original languageEnglish
Pages (from-to)1045-1056
Number of pages12
JournalEuropean Journal of Orthopaedic Surgery and Traumatology
Volume34
Issue number2
DOIs
StatePublished - Feb 2024

Keywords

  • Function
  • Glenoid process
  • Patient outcome
  • Quality of life
  • Scapular notching

Fingerprint

Dive into the research topics of 'Mini-augmented glenoid baseplate and mini-humeral tray reverse total shoulder arthroplasty implant comparisons: two-year clinical outcomes'. Together they form a unique fingerprint.

Cite this