Skip to main navigation Skip to search Skip to main content

Long-term safety and efficacy of the FRED X flow diverter for intracranial aneurysms: a multicenter study of 154 patients

  • Joanna M. Roy
  • , Kareem El Naamani
  • , Cheritesh Amaravadi
  • , Shyam Majmundar
  • , Nikolaos Mouchtouris
  • , Alexandra R. Paul
  • , Nicholas C. Field
  • , Yi Zhang
  • , Jan Karl Burkhardt
  • , Anna Luisa Kühn
  • , Ajit Puri
  • , Elad Levy
  • , M. Reid Gooch
  • , Pascal Jabbour
  • , Robert H. Rosenwasser
  • , Stavropoula I. Tjoumakaris
  • Thomas Jefferson University
  • Albany Medical College
  • Queens University Medical Group
  • University of Pennsylvania
  • University of Massachusetts Boston

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

OBJECTIVE The Flow-Redirection Endoluminal Device X (FRED X) is a newer generation flow diverter with surface modifications aimed at minimizing thrombogenicity. At present, data on its long-term efficacy are limited. This multicenter study presents the largest series within the United States describing the device’s efficacy, safety, and long-term outcomes in treating cerebral aneurysms of varying morphology. METHODS Patients treated with the FRED X for a cerebral aneurysm between February 2022 and February 2024 at 6 high-volume centers across the United States were included. Data were collected regarding demographics, clinical presentation, and procedural efficacy. Angiographic and clinical follow-up outcomes were assessed at 6 and 12 months. RESULTS A total of 154 patients with 162 aneurysms were treated with 164 FRED X devices over the study period. Overall, 81.8% of the cohort was female with a mean age of 56.8 years. The authors observed satisfactory rates (≥ 99.3%) of device deployment and good wall apposition and neck coverage. One hundred forty-seven (95.5%) patients were functionally independent at discharge (modified Rankin Scale scores 0–2). Rates of adequate occlusion (Raymond-Roy Occlusion Scale score I or II) increased from 84.2% at 6 months to 83.5% at the 12-month follow-up, while rates of in-stent stenosis decreased. All patients (100%) who underwent follow-up were functionally independent at 6 months, and 95.9% were functionally independent at 12 months. CONCLUSIONS This multicenter cohort study demonstrates the ease of FRED X deployment with an adequate safety profile, with low rates of procedural complications and favorable outcomes on follow-up. Rates of aneurysm occlusion increased over time, with a subsequent decrease in stent-associated complications.

Original languageEnglish
Pages (from-to)232-242
Number of pages11
JournalJournal of Neurosurgery
Volume143
Issue number1
DOIs
StatePublished - Jul 2025

Keywords

  • aneurysm
  • endovascular neurosurgery
  • flow diversion
  • flow-redirection endoluminal device
  • long-term
  • multicenter
  • vascular disorders

Fingerprint

Dive into the research topics of 'Long-term safety and efficacy of the FRED X flow diverter for intracranial aneurysms: a multicenter study of 154 patients'. Together they form a unique fingerprint.

Cite this