Skip to main navigation Skip to search Skip to main content

Investigation of the efficacy of a data-driven ct artifact correction scheme for sparse and truncated projection data for intracranial hemorrhage diagnosis

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Data-driven CT-image reconstruction techniques for truncated or sparsely acquired projection data to reduce radiation dose, iodine volume, and patient motion artifacts have been proposed. These approaches have shown good performance and preservation of image quality metrics. To continue these efforts, we investigated whether these techniques affect the performance of a machine-learning algorithm to identify the presence of intracranial hemorrhage (ICH). Ten-thousand head CT scans were collected from the 2019 RSNA Intracranial Hemorrhage Detection and Classification Challenge dataset. Sinograms were simulated and then resampled in both a one-third truncated and onethird sparse manner. GANs were tasked with correcting the incomplete projection data in two ways. Firstly, in the sinogram domain, where the incomplete sinogram was filled by the GAN and then reconstructed. Secondly, in the reconstruction domain, where the incomplete data were first reconstructed and the sparse or truncation artifacts were corrected by the GAN. Eighty-five hundred images were used for artifact correction network training, and 1500 were withheld for network assessment via an already trained machine-learning algorithm tasked with diagnosis of ICH presence. Fully-sampled reconstructions were compared with the sparse and truncated reconstructions for classification accuracy. Difference in classification accuracy between the fully sampled (83.4%), sparse (82.0%), and truncated (82.3%) reconstructions was minimal, demonstrating that the network diagnosis performance is unaffected by 2/3 reduction of projection data. This work indicates that data-driven reconstructions for a sparse or truncated projection dataset can provide high diagnostic performance for ICH detection at a fraction of the typical radiation dose.

Original languageEnglish
Title of host publicationMedical Imaging 2021
Subtitle of host publicationPhysics of Medical Imaging
EditorsHilde Bosmans, Wei Zhao, Lifeng Yu
PublisherSPIE
ISBN (Electronic)9781510640191
DOIs
StatePublished - 2021
EventMedical Imaging 2021: Physics of Medical Imaging - Virtual, Online, United States
Duration: Feb 15 2021Feb 19 2021

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume11595
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2021: Physics of Medical Imaging
Country/TerritoryUnited States
CityVirtual, Online
Period02/15/2102/19/21

Keywords

  • Ct artifact correction
  • Intracranial hemorrhage detection
  • Machine learning classification

Fingerprint

Dive into the research topics of 'Investigation of the efficacy of a data-driven ct artifact correction scheme for sparse and truncated projection data for intracranial hemorrhage diagnosis'. Together they form a unique fingerprint.

Cite this