Skip to main navigation Skip to search Skip to main content

Indoor particle contamination in airlaid papermaking workshop

  • Tianjin University

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

An onsite testing based on eight-site air sampling was carried out in an airlaid papermaking workshop in Tianjin, China. By theoretical calculation, super absorbent polymer (SAP) size and its existent state in indoor static airflow were obtained. SAP content in the sampled air was tested through chemical analysis method and found to be 3.0-7.2 times that of the human health limit in production areas. The concentrations of total suspending particles (TSP) and respirable particles were achieved by weighing. Particles of the most concern differ for varied function areas. Particles smaller than 10 μm are mostly produced in the main production process, and 73%-90% particles generated in packing areas are larger than 10 μm. SAP raw material particles can easily changed to suspending form by inevitable extrusion and frication. Correlation between respirable particles and TSP agrees well with that in atmospheric environment.

Original languageEnglish
Pages (from-to)277-280
Number of pages4
JournalTransactions of Tianjin University
Volume12
Issue number4
StatePublished - Aug 2006

Keywords

  • Chemical analysis
  • Industrial pollution
  • Papermaking
  • Particles
  • Testing

Fingerprint

Dive into the research topics of 'Indoor particle contamination in airlaid papermaking workshop'. Together they form a unique fingerprint.

Cite this