Incorporating corrections for the head-holder and compensation filter when calculating skin dose during fluoroscopically guided interventions

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

6 Scopus citations

Abstract

The skin dose tracking system (DTS) that we developed provides a color-coded illustration of the cumulative skin dose distribution on a 3D graphic of the patient during fluoroscopic procedures for immediate feedback to the interventionist. To improve the accuracy of dose calculation, we now have incorporated two additional important corrections (1) for the holder used to immobilize the head in neuro-interventions and (2) for the built-in compensation filters used for beam equalization. Both devices have been modeled in the DTS software so that beam intensity corrections can be made. The head-holder is modeled as two concentric hemi-cylindrical surfaces such that the path length between those surfaces can be determined for rays to individual points on the skin surface. The head-holder on the imaging system we used was measured to attenuate the primary x-rays by 10 to 20% for normal incidence, and up to 40% at non-normal incidence. In addition, three compensation filters of different shape are built into the collimator apparatus and were measured to have attenuation factors ranging from 58% to 99%, depending on kVp and beam filtration. These filters can translate and rotate in the beam and their motion is tracked by the DTS using the digital signal from the imaging system. When it is determined that a ray to a given point on the skin passes through the compensation filter, the appropriate attenuation correction is applied. These corrections have been successfully incorporated in the DTS software to provide a more accurate determination of skin dose.

Original languageEnglish
Title of host publicationMedical Imaging 2015
Subtitle of host publicationPhysics of Medical Imaging
EditorsChristoph Hoeschen, Despina Kontos, Christoph Hoeschen
PublisherSPIE
ISBN (Electronic)9781628415025
DOIs
StatePublished - 2015
EventMedical Imaging 2015: Physics of Medical Imaging - Orlando, United States
Duration: Feb 22 2015 → Feb 25 2015

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9412
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2015: Physics of Medical Imaging
Country/TerritoryUnited States
CityOrlando
Period02/22/15 → 02/25/15

Keywords

  • Compensation filter
  • Dose tracking
  • Fluoroscopic interventional procedures
  • Head holder
  • Skin dose