Skip to main navigation Skip to search Skip to main content

In vivo canine study of three different coatings applied to p64 flow-diverter stents: initial biocompatibility study

  • Rosa Martínez Moreno
  • , Pervinder Bhogal
  • , Tim Lenz-Habijan
  • , Catrin Bannewitz
  • , Adnan Siddiqui
  • , Pedro Lylyk
  • , Ralf Hannes
  • , Hermann Monstadt
  • , Hans Henkes
  • Hospital Universitario Virgen de las Nieves
  • Barts Health NHS Trust
  • phenox GmbH
  • Equipo de Neuro. End. y Radiol. Inter. de Buenos Aires-Clin. la Sagrada Familia
  • Klinikum Stuttgart
  • University of Duisburg-Essen

Research output: Contribution to journalArticlepeer-review

44 Scopus citations

Abstract

BACKGROUND: Flow-diverter stents (FDSs) have revolutionised the treatment of intracranial aneurysms. However, associated dual antiplatelet treatment is mandatory. We investigated the biocompatibility of three proprietary antithrombogenic coatings applied to FDSs. METHODS: After Institutional Animal Care and Use Committee approval, four domestic juvenile female dogs (weight 19.9 ± 0.9 kg, mean ± standard deviation) were commenced on three different oral antiplatelet regimes: no medication (n = 1), acetylsalicylic acid (n = 2), and acetylsalicylic acid and clopidogrel (n = 1). Four p64 FDSs were randomly implanted into the subclavian, common carotid, and external carotid arteries of each dog, including both uncoated p64 stents and p64 stents coated with three different antithrombogenic hydrophilic coating (HPC). Angiography and histological examinations were performed. Wilcoxon/Kruskal-Wallis and ANOVA were used with p value < 0.05 considered as significant. RESULTS: Minimal inflammatory cell infiltration and no device-associated granulomatous cell inflammation were observed. No significant difference in adventitial inflammation (p = 0.522) or neointimal/medial inflammation (p = 0.384) between coated and uncoated stents as well as between the different stent groups regarding endothelial cell loss, surface fibrin/platelet deposition, medial smooth muscle cell loss, or adventitial fibrosis were found. Acute self-limiting thrombus formed on 6/16 implants (37.5%), and all of the thrombi were noted on devices implanted in the common or external carotid artery irrespective of the surface coating. Two of 12 p64 HPC-coated stents (16.7%) and 1/4 uncoated p64 stents (25%) showed severe or complete stenosis at delayed angiography. CONCLUSIONS: In these preliminary in vivo experiments, HPC-coated p64 FDSs appeared to be biocompatible, without acute inflammation.

Original languageEnglish
Pages (from-to)3
Number of pages1
JournalEuropean Radiology Experimental
Volume3
Issue number1
DOIs
StatePublished - Jan 22 2019

Keywords

  • Biocompatible materials
  • Disease models (animal)
  • Intracranial aneurysm
  • Materials testing
  • Stents

Fingerprint

Dive into the research topics of 'In vivo canine study of three different coatings applied to p64 flow-diverter stents: initial biocompatibility study'. Together they form a unique fingerprint.

Cite this