Abstract
Oxidation treatments of steel rebar by water immersion (2-5 days) and ozone exposure increased the bond strength between steel rebar and concrete by 14% and 22% respectively. The treatments slightly increased the electrical contact resistivity between rebar and concrete. Increase of the water immersion time to 7 or 10 days caused the bond strength to decrease to values still above that of the case without water treatment. The contact resistivity increased monotonically with the water immersion time.
| Original language | English |
|---|---|
| Pages (from-to) | 1499-1503 |
| Number of pages | 5 |
| Journal | Cement and Concrete Research |
| Volume | 26 |
| Issue number | 10 |
| DOIs | |
| State | Published - Oct 1996 |
Fingerprint